[:lt]Pool Line pH ir mV tikslus simuliatorius – HI9310014[:en]Pool Line pH and mV Precision Simulator – HI9310014[:] — Pool Line pH and mV Precision Simulator – HI9310014 [:lt]HI98161 Bendrosios paskirties Foodcare pH ir temperatūros matuoklis[:en]HI98161 General Purpose Foodcare pH and Temperature meter[:] HI98161 General Purpose Foodcare pH and Temperature meter —

Portable pH/ORP Meter – HI98190

632.50  + PVM

The professional, waterproof meter complies with IP67 standards and measures pH, ORP and temperature.

SKU: HI98190 Categories: ,

Available on backorder - This item may take 2-3 weeks to deliver.

Details

For the measurement of pH, the portable pH meter HI98190 comes with an HI12963 titanium body amplified pH electrode with a built-in temperature sensor for automatic temperature compensated readings. The titanium probe body is chemically resistant to aggressive chemicals and is virtually unbreakable. The HI12963 pH/temperature electrode features a newly designed Quick Connect DIN connector that provides a simple waterproof connection without any threads.

Hanna’s unique CAL Check™ feature alerts the user to potential problems during the calibration process. By comparing previous calibration data to the current calibration, the pH meter will alert the user with display prompts when the probe needs to be cleaned or is broken, and if the pH buffer might be contaminated. After calibration, the overall probe condition is displayed as a percentage from 0 to 100% in increments of 10%. The probe condition is affected by both the offset and slope characteristics of the pH electrode and is displayed on the measurement screen on the day of calibration and in the GLP data. Calibration can be performed up to five points with seven preprogrammed standard pH buffers and five custom ones to achieve a pH accuracy of ±0.002 with ±0.001 pH resolution.

Pressing the “AutoHold” virtual key seen in measurement mode, the meter will freeze a stable reading, allowing for the reading to be documented or logged. An “out of calibration range” warning can be enabled that will alert the user when a reading is not within the bracket of calibrated pH values.

The log-on-demand mode allows the user to record and save up to 200 samples (100 for pH and 100 for mV). This data, along with the associated GLP data, can then be transferred to a PC with Hanna’s HI920015 micro USB cable and HI92000 software.

The high contrast graphic LCD is easy to read outdoors in bright sunlight as well as in low-lit areas with the use of the backlight. A combination of dedicated and virtual keys allows easy, intuitive operation in a choice of languages.

The compact, durable carrying case is thermoformed to hold all necessary components for taking a field measurement, including the meter and electrode, beakers, buffer solutions, cleaning solutions, and storage solutions.

 

Setup screen

Our extensive setup screen features a host of configurable options such as time, date, temperature units and language for help screens and guides.

Calibration

pH calibration features detailed CAL Check™ messages. Users are guided through the calibration procedure with step-by-step on-screen instructions.

GLP

Comprehensive GLP functions are directly accessible by pressing the GLP key. Calibration data, including: date, time, offset, slope and buffers used in the last calibration can be reviewed.

 

  • Ergonomic, rugged, waterproof (IP67) design
  • pH CAL Check™
    • Alerts user to potential problems during calibration including when to clean electrode and possible buffer contamination.
    • Displays overall probe condition based on offset and slope after calibration
  • Automatic Temperature Compensation
  • Five-point pH calibration with seven standard buffers and five custom buffers
  • Log-on-demand
    • Store measurement data at the press of a button
  • AutoHold – freezes reading on display upon stabilization
  • GLP features
    • GLP data including date, time, pH calibration buffers, offset and slope
  • Calibration timeout to alert the user at a defined interval when the calibration has expired
  • Multiple language selection
  • 200 hour battery life with battery level displayed on measurement screen
  • Menu driven for ease of use with virtual-key extended functionality
  • Contextual help at the press of a button
  • Backlit, graphic LCD
  • Connectivity
    • PC connectivity via a sealed opto-isolated micro USB and HI92000 software

 

 

Supplied with

  • HI-12963 titanium body pH electrode
  • HI-7004M
  • HI-7007M
  • 2 x sachets of electrode cleaning solution
  • Rugged carrying case
  • 100mL plastic beaker (2)
  • HI-92000 PC software
  • HI-920015 micro USB cable
  • Batteries
  • Instruction manual
  • Quality certificate

 

 

Specifications

pH Range   -2.0 to 20.0 pH; -2.00 to 20.00 pH; -2.000 to 20.000 pH
pH Resolution   0.1 pH; 0.01 pH; 0.001 pH
pH Accuracy   ±0.1 pH; ±0.002 pH
pH Calibration   up to five-point calibration, seven standard buffers available (1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) and five custom buffers
Temperature Compensation   automatic or manual from -20.0 to 120.0°C
mV Range   ±2000 mV
mV Resolution   0.1 mV
mV Accuracy   ±0.2 mV
Relative mV Offset Range   ±2000 mV
Temperature Range   -20.0 to 120.0°C
Temperature Resolution   0.1°C
Temperature Accuracy   ±0.4°C
Additional Specifications:    
pH Probe   HI-12963 titanium body, pH electrode with internal temperature sensor, quick DIN connector and 1m cable
Slope Calibration   from 80 to 110%
Log-on-demand   200 samples (100 each pH/mV range)
PC Connection   opto-isolated USB with HI-92000 software and micro USB cable
Input Impedance   10¹²Ω
Battery Type/Life   1.5 C AA batteries (4) / approximately 200 hours of continuous use without backlight (50 hours with backlight)
Auto-off   user selectable; 5, 10, 30, 60 min, disabled
Environment   0 to 50°C; RH 100 % IP67
Dimensions/Weight   185 x 93 x 35.2 mm / 400g

Additional Informations

Industry Aquaculture and aquariums, Environment, Industrial
Parameter ORP, pH
 

Related products