[:lt]Elektrodo laikymo tirpalas, 120 ml - HI5300-12[:en]Electrode storage solution, 120 ml[:] — Electrode storage solution, 120 ml [:lt]Modulinis daugiaparametrinis stalinis matuoklis su dviem pH/ORP moduliais HI6222-02[:en]Modular multiparameter benchtop meter with two pH/ORP modules HI6222-02[:] Modular multiparameter benchtop meter with two pH/ORP modules HI6222-02 —

Modular multiparameter benchtop meter with pH/ISE and EC module HI6522-02

1,424.00  + PVM

supplied with HI6000 housing unit with electrode holder, HI6000-2 pH/ISE module + HI1131B pH electrode + HI7662-TW temperature probe, HI6000-3 EC module + HI7631233 EC probe and calibration starter kit

SKU: HI6522-02 Categories: ,

Available on backorder - This item may take 2-3 weeks to deliver.

Order info:
 

supplied with HI6000 housing unit with electrode holder, HI6000-2 pH/ISE module + HI1131B pH electrode + HI7662-TW temperature probe, HI6000-3 EC module + HI7631233 EC probe and calibration starter kit

product-info-hi6000-modular-en

 

The new HI6000 Series modular multiparameter touchscreen laboratory system is designed for research and laboratory professionals who demand impeccable measurement quality. HI6000 is a fully flexible measurement platform that can be customized according to the user’s application needs. Designed and developed using the latest generation technologies it gives complete control over measurements.

Modular by nature, HI6000 allows simultaneous installation of three out of four available modules: pH/ORP, pH/ORP/ISE, Dissolved Oxygen and Conductivity. Combined with the appropriate sensors, the device provides fast, reliable measurements displayed on the large touchscreen. A context-sensitive help menu and tutorial videos support the user through all operations, for a very user-friendly experience.

The instrument features numerous functions to simplify and optimize work routines, such as a wide choice of display modes, installation of application profiles for immediate access to recurring methods, and versatile connectivity for data storage and sharing.

  • Four modules available: pH/ORP, pH/ORP/ISE, DO, & EC
  • Totally flexible and customizable
  • View up to three channels simultaneously
  • Share data via Wi-Fi or Ethernet
  • Quick assistance with video tutorials

HI6000

Go Modular

Hanna Instruments offers four different measurement modules for pH/ORP, pH/ORP/ISE, DO, and EC. Easily install and swap up to three modules in the space saving design. Any combination of 1 to 3 modules can be used for total flexibility in measurements. Even if you don’t need to measure different parameters: your lab is now future-proof!

Next-level customisation of views, user accounts and application-specific profiles allows for quick and direct measurement without the need to update settings.

> HI6000-1 plugin module for pH/ORP
> HI6000-2 plugin module for pH/ORP/ISE
> HI6000-3 plugin module for EC
> HI6000-4 plugin module for DO

https://youtu.be/mpqdA2T4ONc

 


Accurate & Reliable

Together with appropriate electrodes, the meter provides highly accurate and reliable measurement for all laboratories.

Up to three measurement channels can be viewed simultaneously. Views can be mixed and matched. Data can be shown basic or in full detail, in a table or plotted as graph.

The HI6000 Series allows for up to 5-point calibration for pH, ISE and Conductivity for optimum results.

  • pH calibration up to 5 points with 8 stored standard buffers and 5 custom buffers
  • ISE calibration up to 5 points with 5 stored standards and 5 custom buffers
  • Conductivity calibration up to 5 points with 6 stored standards and 1 user standard

Hanna Instruments also offers a wide range of high quality pH electrodes for many applications. Contact us to find the right electrode for your needs.

HI6000

HI6000

Go digital

The HI6000 Series help you avoid errors caused by manual transcription of results, thanks to an incredible simple and flexible data management! The instrument can store up to 1,000,000 data points for each user. Data can be shared via Wi-Fi, Ethernet, email, web server, USB flash drive or PC. No software required!

Conveniently connect a keyboard, a printer or two stirrers to improve your workflow.


Seamless simplicity

The HI6000 multiparameter features a user friendly design for effortless control and seamless simplicity. The benchtop unit has a large capacitive touch screen with multi-touch support.

The help menu supports you with an overview of the main functionalities through text and video tutorials for quick assistance.

User-friendly interface

  • User-friendly icons and symbols enable easy navigation and interpretation of instrument functions
  • Choice of five different display modes: Standard, Simple GLP with calibration information, Full GLP with electrode status and calibration point details, Interactive graph updated in real time, Tabulated data with date, time and notes

10 user profiles

  • For direct access to daily analyses, users can save their procedures in profiles grouping together all their method configuration data.

On-board help and video tutorials

  • The help menu supports users with a brief overview of the system’s main functionalities through text and video tutorials.
HI6000

HI6000

Stay secure

Certification

Our technical department offers a comprehensive certification and periodic calibration service, ensuring that your measuring instruments are always reliable and comply with the required standards. Each instrument, module, and probe is provided with a quality certificate, guaranteeing their high performance.
Regular maintenance of instruments is essential for those operating quality management systems, as it helps maintain precision and reliability in measurements, aspects that can be verified during audits.ch can be checked during an audit.

“Measuring equipment needs to be checked periodically. With Hanna Instruments calibration services, you can ensure the reliability and quality of your measuring equipment. You optimize their smooth operation and reduce your costs.”

Support

Our technical team is here to help you.

  • Phone support
  • Quick assistance
  • Advice on choosing the right electrodes for your application
  • Calibration services
  • Repairs on our premises
SPECIFICATION:

 

ORDER INFORMATION:

supplied with HI6000 housing unit with electrode holder, HI6000-2 pH/ISE module + HI1131B pH electrode + HI7662-TW temperature probe, HI6000-3 EC module + HI7631233 EC probe and calibration starter kit.

The HI6000-2 module measures pH, ORP, specific ions and temperature.

Measurement

  • Choice of Measurement Unit
    • pH (HI6000-1, HI6000-2) – pH, mV
    • ORP (HI6000-1, HI6000-2) – mV, Rel.mV
    • ISE (HI6000-2 only) – ppt, ppm, ppb, g/L, mg/L, μg/L, mg/mL, μg/mL, M, mol/L, mmol/L, %w/v, user defined
  • Reading modes:
    • Direct and direct/autohold
    • Known Addition, Known Subtraction, Analyte Addiiton,
    • Analyte Subtration (HI6000-2)

Calibration

  • pH calibration using
    • Up to five Hanna Instruments pH buffers (pH 1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01 and 12.45)
    • Up to five custom buffers
  • mV calibration using a single point to calibrate offset.
  • ISE calibration using up to five nominal standard values and/or up to five custom solutions (user supplied)

Recommended probes

For pH measurements, Hanna recommends the HI1131B double junction combination pH electrode, together with HI7662-TW temperature probe for use with these modules.

HI1131B is a glass body, double junction, refillable pH electrode with an indicating sensor made of high temperature (HT) glass. The double junction reference and HT glass design allow the electrode to be used in a
wide variety of applications.

Probe connection to the unit is secured through a galvanically isolated BNC connection.

HI7662-TW stainless steel temperature probe allows the meter to automatically temperature compensate (ATC) pH measurements.

 

Specifications

Specification HI6000-2
pH Range -2.0 to 20.0 pH; -2.00 to 20.00 pH; -2.000 to 20.000 pH
pH Resolution 0.1 pH; 0.01 pH; 0.001 pH
pH Accuracy ±0.1 pH; ±0.01 pH; ±0.002 pH (±1 last significant digit)
Temperature Compensation Automatic or manual
Calibration Points Up to 5
Calibration Type Automatic; Semiautomatic; Manual
Standard Buffers Hanna and NIST pH 1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45
Custom Buffers Up to 5
Custom Group Up to 5
1st Calibration Point Offset or point (user setting)
Isopotential Point -2.000 to 20.000 pH
mV Range -2000.0 mV to 2000.0 mV
mV Resolution 1 mV; 0.1 mV
mV Accuracy ±0.2 mV ±1 last significant digit
mV Calibration Single point offset, ±2000.0 mV
ISE Range 1.0×10⁻⁵ to 300.0 ppt (g/L or mg/mL); 5.0×10⁻³ to 1.0×10⁵ ppm (mg/L or μg/mL); 1.0 to 5.0×10⁷ ppb (μg/L); 1.0×10⁻⁷ to 10.0 M (mol/L); 1.0×10⁻⁴ to 1.0×10⁴ mmol/L; 1.0×10⁻⁶ to 60.0 % w/v; 5.0×10⁻⁷ to 5.0×10⁷ user
ISE Resolution 1, 2, 3 significant digits
ISE Accuracy ±0.5% (monovalent ions); ±1% (divalent ions)
ISE Calibration Points Up to 5
ISE Calibration Type All standards
Standard group
Standards 7 standard solutions available for each concentration unit
Custom Standards Up to 5
Custom Group Up to 5
Temperature Range -20.0 to 120.0 °C; -4.0 to 248.0 °F; 253.2 to 393.2 K
Temperature Resolution 0.1 °C; 0.1 °F ; 0.1 K
Temperature Accuracy ±0.2 °C; ±0.4 °F; ±0.2 K
Temperature Calibration Single point, adjustable

The HI6000-3 module measures conductivity over an extended range from 0.001 μS/cm to 1 S/cm, TDS, resistivity, salinity and temperature.

The HI6000-3 module also supports the measurement of high purity water used in the pharmaceutical industry. The application includes meter verification, cell validation applications and the HI6000-3 module is programmed for the three stages of the USP <645> bulk water analysis. The meter guides you through the measurement steps and notifies you when a measurement is out of specification. Reports can be generated and saved.

Measurement

  • Choice of Measurement Unit
    • Conductivity – μS/cm, mS/cm
    • Resistivity – Ω·cm, kΩ·cm, MΩ·cm
    • TDS – ppm, ppt
    • Salinity – ppt, PSU, %

Calibration

  • Conductivity Calibration up to five points, using:
    • Offset: 0 μS/cm (in air)
    • Slope: 84 μS/cm, 1413 μS/cm, 5000 μS/cm, 12880 μS/cm, 80000 μS/cm, and 111800 μS/cm, or custom standards
  • Salinity (%) calibration using 100% salinity standard

Specifications

Specifications HI6000 with HI6000-3 EC Module
Conductivity Range* 0,000 to 9,999 μS/cm
10,00 to 99,99 μS/cm
100,0 to 999,9 μS/cm
1,000 to 9,999 mS/cm
10,00 to 99,99 mS/cm
100,0 to 1000,0 mS/cm
Resolution 0,001 μS/cm
0,01 μS/cm
0,1 μS/cm
0,001 mS/cm
0,01 mS/cm
0,1 mS/cm
Accuracy ±1 % of reading or ±0,010 μS/cm, whichever is greater
Cell Constant 0,0500 to 200,0000 /cm
Calibration Type Automatic or manual
Calibration Points Single; Up to 5
Calibration Solutions 84,00 μS/cm; 1,413 mS/cm; 5,000 mS/cm; 12,88 mS/cm; 80,00 mS/cm; 111,8 mS/cm
Temperature Compensation Linear; Natural; Standard; Disabled
Reference Temperature 5,0 to 30,0 °C (41,0 to 86,0 °F, 278,2 to 303,2 K)
Temperature Coefficient 0,00 to 10,00 %/°C
Resistivity Range 1,0 to 99,9 Ω·cm; 100 to 999 Ω·cm; 1,00 to 9,99 KΩ·cm; 10,0 to 99,9 KΩ·cm; 100 to 999 KΩ·cm; 1,00 to 9,99 MΩ·cm; 10,0 to 100,0 MΩ·cm
Resolution 0,1 Ω·cm; 1 Ω·cm; 0,01 KΩ·cm; 0,1 KΩ·cm; 1 KΩ·cm; 0,01 MΩ·cm; 0,1 MΩ·cm
Accuracy ±1 % of reading or ±1 Ω·cm, whichever is greater
Total Dissolved Solids (TDS) Range 0,000 to 9,999 ppm
10,00 to 99,99 ppm
100,0 to 999,9 ppm
1,000 to 9,999 ppt
10,00 to 99,99 ppt
100,0 to 400,0 ppt (actual TDS with 1.00 factor)
Resolution 0,001 ppm
0,01 ppm
0,1 ppm
0,001 ppt
0,01 ppt
0,1 ppt
Accuracy ±1 % of reading or ±0,01 ppm, whichever is greater
Salinity Range 0.00 to 42.00 PSU (Practical Salinity Scale)
0.00 to 80.00 ppt (Natural Sea Water)
0.0 to 400.0 % (Percent Scale)
Resolution 0.01 PSU
0.01 ppt
0.1 %
Accuracy ±1 % of reading
Calibration 1 point, using 100 % salinity calibration solution (% scale only)
Temperature Range* -20,0 to 120,0°C / -4,0 to 248,0°F / 253,2 to 393,2K
Resolution 0,1°C; 0,1°F; 0,1K
Accuracy ±0,2°C; ±0,4°F; ±0,2K
Calibration Single point, adjustable

*The range may be limited by the probe’s limits.


Related products