HI3512 is a dual-input professional pH/ORP/ISE/EC/Resistivity/TDS/NaCl/Temperature bench meter with a graphic LCD designed to provide high accuracy and ease of use both in the laboratory as well as in harsh industrial conditions. This instruments is a dual-input model measuring pH, ORP, or ISE and temperature on channel 1 and EC, Resistivity, TDS, and Salinity (utilizing an EC probe) on channel 2.
This meter features Hanna’s exclusive Calibration Check™, a diagnostics system that ensures accurate readings every time. Calibration Check system eliminates erroneous readings due to dirty or faulty pH electrodes or contaminated buffer solution by alerting users of potential problems during the calibration process.
Throughout the calibration process, users are guided step-by-step by the on-screen tutorial. After calibration, a probe condition indicator is displayed on the LCD informing the user of the overall electrode status.
A variety of interactive user support is available before, during and after measurement. Onscreen tutorials guide users through set-up, calibration and measurement while context sensitive help of any screen is available at a push of a button. The HELP screen accessed by a dedicated HELP button, includes language specific assistance for menu parameters, calibration, log, contact information and accessories for your instrument.
Main Features:
- Dual-input channel
- pH/mV/ISE and temperature measurements (Channel 1)
- EC/TDS, NaCl/Resistivity and temperature measurements (Channel 2)
- Up to 5 point pH calibration with 7 standard buffers and 2 custom buffers to choose from
- Up to two points EC calibration with 7 memorized standards for calibration to choose from
- Messages on the graphic LCD for an easy and accurate calibration
- Diagnostic features to alert the user when the electrode needs cleaning
- Relative mV measurements
- Log on demand up to 400 samples
- Log interval with log on stability feature up to 600 records
- Auto Hold feature, to freeze first stable reading on the LCD
- GLP, last calibration data for pH, Rel mV, ISE, EC, or NaCl
- PC interface
Primary Applications:
- Laboratory, Industrial
Specifications:
|
pH
|
Range | –2.0 to 20.0 pH –2.00 to 20.00 pH –2.000 to 20.000 pH |
| Resolution | 0.1 pH 0.01 pH 0.001 pH |
|
| Accuracy | ±0.01 pH ±0.002 pH |
|
| Calibration | Up to 5 points 7 standard buffers (1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) 2 custom buffers |
|
|
ORP
|
Range | ±2000.0 mV |
| Resolution | 0.1 mV | |
| Accuracy | ±0.2 mV | |
|
ISE
|
Range | 1.00 E-7 to 9.99 E10 conc. |
| Resolution | 3 digits 0.01, 0.1, 1, 10 conc. | |
| Accuracy | ±0.5% of reading (monovalent ions) ±1% of reading (divalent ions) |
|
| Calibration | Up to 5 points 6 standards (0.1, 1, 10, 100, 1000, 10000 ppm) |
|
|
Temperature Channel 1
|
Range | –20.0 to 120.0 °C (–4.0 to 248.0 °F) |
| Resolution | 0.1 °C (0.1 °F) | |
| Accuracy | ±0.2 °C (±0.4 °F) (excluding probe error) | |
| Rel mV offset range | ±2000 mV | |
| Slope calibration | From 80 to 110% | |
| pH Temperature compensation | Manual Automatic |
|
| Electrode | Hanna BNC connection pH / ORP / ISE electrodes | |
| Temperature probe | RCA connection Recommended option: HI7662-TW |
|
|
EC
|
Range | 0 to 400 mS/cm (shows values up to 1000 mS/cm) Actual conductivity 1000 mS/cm 0.001 to 9.999 μS/cm 10.00 to 99.99 μS/cm 100.0 to 999.9 μS/cm 1.000 to 9.999 mS/cm 10.00 to 99.99 mS/cm 100.0 to 999.9 mS/cm 1000 mS/cm (autoranging) |
| Resolution | 0.001 μS/cm 0.01 μS/cm 0.1 μS/cm 0.001 mS/cm 0.01 mS/cm 0.1 mS/cm 1 mS/cm |
|
| Accuracy | ±1% of reading (±0.01 μS/cm or 1 digit whichever greater) excluding probe error |
|
| Calibration | Up to 2 points 7 standards (0.00 μS/cm, 84.0 μS/cm, 1.413 mS/ cm, 5.00 mS/cm,12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) |
|
|
Resistivity
|
Resolution | 1.0 to 99.9 ohms 100 to 999 ohms 1.00 to 9.99 Kohms 10.0 to 99.9 Kohms 100 to 999 Kohms 1.00 to 9.99 Mohms 10.0 to 100.0 Mohms (autoranging) |
| Accuracy | 0.1 ohm 1 ohm 0.01 Kohms 0.1 Kohms 1 Kohms 0.01 Mohms 0.1 Mohms |
|
| Calibration | ±1% of reading (±10 ohms or 1 digit whichever greater) excluding probe error |
|
|
TDS
|
Range | 0.000 to 9.999 ppm 10.00 to 99.99 ppm 100.0 to 999.9 ppm 1.000 to 9.999 g/L 10.00 to 99.99 g/L 100.0 to 400.0 g/L (autoranging) |
| Resolution | 0.001 ppm, 0.01 ppm, 0.1 ppm 0.001 g/L, 0.01 g/L, 0.1 g/L |
|
| Accuracy | ±1% of reading (±0.05 ppm or 1 digit whichever greater) excluding probe error |
|
| TDS Factor | 0.40 to 1.00 | |
|
Salinity
|
Range | % NaCl: 0.0 to 400.0 % |
| Resolution | 0.1% | |
| Accuracy | ±1% of reading excluding probe error | |
|
Temperature Channel 2
|
Range | −20.0 to 120.0 °C (4.0 to 248.0 °F) |
| Resolution | 0.1 °C / 0.1 °F | |
| Accuracy | ±0.2 °C (excluding probe error) | |
| Cell constant setup | 0.010 to 10.000 | |
| NaCl Calibration | Max. 1 point only (with HI7073 standard) | |
| EC probe | DIN connection Recommended option: HI76310 |
|
| Temperature source | Automatic Manual |
|
| EC temperature compensation |
NoTC, MTC, ATC | |
| Reference temperature | 15, 20, 25 °C | |
| Temperature coeficient | 0.00 to 10.00 %/°C | |
| Log on demand | 400 samples | |
| Lot logging | 5, 10, 30 seconds 1, 2, 5, 10, 15, 30, 60, 120, 180 minutes, AutoEnd (maximum 600 samples) |
|
| Environment | 0 to 50 °C (32 to 122 °F) max. RH 55% non-condensing |
|
| Power supply | 12 Vdc power adapter | |
| PC interface | opto-isolated USB | |
| Dimensions | 235 x 207 x 110 mm (9.2 x 8.14 x 4.33”) | |
| Weight (meter only) | 1.8 Kg (4.1 lb) | |
Ordering Information:
HI3512-01 (115V) and HI3512-02 (230V) is supplied with:
- Benchtop meter
• HI1131B pH electrode
• HI76310 Conductivity probe
• HI7662-TW Temperature probe
• HI76404W Electrode holder
• pH 4.01 buffer solution, 20 mL sachet
• pH 7.01 buffer solution, 20 mL sachet
• Cleaning solution, 20 mL, 2 sachets
• Electrolyte solution
• Capillary pipette
• 12 Vdc power adapter
• Instrument quality certificate with quick reference guide
• Electrode | probe quality certificates with quick reference guides
Accessories:
(*denotes preferred accessories for web when space is a concern)
Please refer to instruction manual for full accessory list.
pH Buffer Solution
HI5016 pH 1.68 Buffer Solution, 500 mL bottle
*HI5004 pH 4.01 Buffer Solution, 500 mL bottle
HI5068 pH 6.86 Buffer Solution, 500 mL bottle
*HI5007 pH 7.01 Buffer Solution, 500 mL bottle
HI5091 pH 9.18 Buffer Solution, 500 mL bottle
*HI5010 pH 10.01 Buffer Solution, 500 mL bottle
HI5124 pH 12.45 Buffer Solution, 500 mL bottle
pH Electrodes
HI1043B Glass-body, double junction, refillable, combination pH electrode.
Use: strong acid/alkali.
HI1053B Glass-body, triple ceramic, conic shape, refillable, combination pH electrode.
Use: emulsions.
*HI1083B Glass-body, micro, Viscolene, non-refillable, combination pH electrode.
Use: biotechnology, micro titration.
*HI1131B Glass-body, double junction, refillable, combination pH electrode.
Use: general purpose.
HI1330B Glass-body, semimicro, single junction, refillable, combination pH electrode.
Use: laboratory, vials.
HI1331B Glass-body, semimicro, single junction, refillable, combination pH electrode.
Use: flasks.
*HI1230B Plastic-body (PEI), double junction, gel-filled, combination pH electrode.
Use: general, field.
FC911B Plastic-body (PVDF), double junction, refillable with built-in amplifier, combination pH
electrode.
Use: very high humidity.
*HI1413B Glass-body, single junction, flat tip, Viscolene, non-refillable, combination pH
electrode.
Use: surface measurement.
ORP Electrodes
*HI3230B Plastic-body, gel-filled, combination platinum ORP electrode. Use: general purpose.
ORP Pretreatment Solutions
HI7091L Reducing Pretreatment Solution, 500 mL bottle +14 g (set)
HI7092L Oxidizing Pretreatment Solution, 500 mL bottle
Electrode Cleaning Solution
*HI7061L General Purpose Solution, 500 mL bottle
Electrode Storage Solution
*HI70300L Storage Solution, 500 mL bottle
EC Probe
*HI76310 Platinum, four-ring EC/TDS probe with a built-in temperature sensor and DIN
connection
EC Calibration Solutions
HI6033 84 μS/cm, 500 ml, bottle
HI6031 1413 μS/cm, 500 ml, bottle
HI7039L 5000 μS/cm, 500 ml, bottle
HI7030L 12880 μS/cm, 500 ml, bottle
HI7034L 80000 μS/cm, 500 ml, bottle
HI7035L 111800 μS/cm, 500 ml, bottle
HI7037L 100% NaCl, 500 ml, bottle