[:lt]Bendrosios paskirties Pt100 zondas - HI768P[:en]General Purpose Penetration Pt100 Probe - HI768P[:] — Bendrosios paskirties Pt100 zondas - HI768P Conductivity Mini Controller (0.00-10.00 mS/cm) - BL983317 Conductivity Mini Controller (0.00-10.00 mS/cm) - BL983317 —

Resistivity Mini Controller – BL983314

285.00  + PVM

Black Stone

Produkto kodas: BL983314-0 Kategorija:

Tik išankstinis užsakymas - prekės pristatytas gali trukti 2-3 savaites.

The BL-983314 is a simple to operate resistivity controller designed for ultra pure water, reverse osmosis, and water conditioning applications. The BL-983314 resistivity controller is also ideal for continuous monitoring to process solutions. Setpoint and calibration are manually adjusted with a trimmer and the alarm relay allows for simple control

 

Details

About the BL-983314 Resistivity Mini Controllers

  • Fire retardant casing
  • Selectable overdose protection system
  • Splash-resistant cover

 

Readings are automatically temperature compensated with three different coefficients (β=2.4, 3.5 or 4.5 %/°C). The alarm contact can be used for connection to an alarm, pump, solenoid or dosing system.

The relay contact is open when readings are higher than the setpoint, while for measurements lower than setpoint, the relay contact is closed. The hysteresis is typically 0.20 MΩ •cm from the setpoint.

Measurements are displayed on the LCD and the multi-coloured LED continuously indicates if the controller is in measurement, dosing, or alarm mode. Users can choose automatic or manual dosing mode with a switch on the front panel. Manual control is particularly useful during maintenance operations, because it permits operators to enable or disable the dosing relay according to need.

The overtime control system advises users when the relay is active for too long, helping to prevent over-dosage.

Range 0.00 to 19.90 MΩ•cm
Resolution 0.10 MΩ•cm
Accuracy (@25°C/77°F) ±2% F.S.
Calibration factory calibrated
Dosing Relay maximum 2A (fuse protected), 250 Vac, 30 Vdc contact closed when measure < setpoint
Setpoint adjustable from 0 to 19.90 MΩ•cm
Overtime adjustable, typically from 5 to approximately 30 minutes
Temperature Compensation automatic and linear from 5 to 50°C (41 to 122°F) [β=2.4 ; 3.5 ; 4.5 %/°C selectable through jumper on the rear panel]
Power Supply BL983314-0: 12 VDC adapter (included); BL983314-1: 115/230 VAC; 50/60Hz
Power Consumption 10 VA
Dimensions 83 x 53 x 99 mm (3.3×2.1×3.9”)
Weight BL983314-0: 200 g (7.1 oz.); BL983314-1: 300 g (10.6 oz.)
Ordering Information BL983314-0 (12 VDC) and BL983314-1 (115/230V) are supplied with HI3314 resistivity probe with 2 m (6.6’) cable, mounting brackets, transparent cover and instruction manual.

Papildoma informacija

Svoris 0.667 kg