[:lt]HI97715 - Amoniako vidutinio diapazono nešiojamas fotometras su CAL Check sistema[:en]Ammonia Medium Range Portable Photometer with CAL Check - HI97715[:] — Ammonia Medium Range Portable Photometer with CAL Check - HI97715 [:lt]HI97700 Amoniako mažo diapazono nešiojamas fotometras su CAL Check sistema[:en]HI97700 Ammonia Low Range Portable Photometer with CAL Check[:] HI97700 Ammonia Low Range Portable Photometer with CAL Check —

HI97715C KIT – Ammonia Medium Range portable photometer with CAL Check

500.50  + PVM

KIT – Ammonia Medium Range portable photometer with CAL Check

SKU: HI97715C Categories: ,

Available on backorder - This item may take 2-3 weeks to deliver.

HI97715C is an advanced portable photometer for the Medium Range measurement of ammonia in water.  This meter offers a superior optical system that utilizes a reference detector and narrow band interference filters for extremely fast and repeatable measurements.

    • No warm up time before taking a measurement
    • Tutorial mode for step-by-step instructions
    • Display results in multiple chemical forms 

 

HI97715C is supplied with CAL-Check standards, cuvettes (2), caps (2), plastic inserts for cuvette, (2), scissors, cuvette cleaning cloth, 1.5V AA batteries (3), instruction manual, and instrument quality certificate. The HI97715 has an innovative optical system that offers superior performance in accuracy, repeatability, and the short amount of time it takes to perform a measurement. This compact, waterproof meter is extremely user friendly with a tutorial mode that walks the user graphically, step by step, in performing a measurement. The use of a backlit dot matrix LED allows the use of virtual keys which makes the operation of the meter very intuitive including selecting different units of measure, reviewing GLP data, recalling the last 50 measurements, and customizing the meter to user preferences.

HI97715 is completely waterproof including the cuvette holder that is designed with ridges to protect the optical path from getting scratched by the cuvette and a gasketed battery compartment that holds three common AA batteries. The compact design fits comfortable in the hand for use in the field or on a table for benchtop use. The LCD is 71 mm (2.75″) by 37 mm (1.6″) and is backlit for easy viewing under all conditions.

photometer optical system

  • LED that generates very little heat
  • 8 nm narrowband interference filter that is accurate to +/- 1 nm and offers 25% increase in light efficiency.
  • Reference detector that modulates the voltage to LED for consistent light output. 
  • A concave focusing lens that reduces errors from imperfections in the cuvette

 

On-Screen Features

CAL Check HI97700
CAL Check
Advanced features including CAL-Check to verify performance, GLP for last calibration date, setup options and the ability to see all accessories used with the meter.

 

tutorial mode HI97700
Tutorial Mode
When enabled, the tutorial mode will guide the user step by step through the measurement process .

 

method option
Method Options
Results can be displayed in multiple chemical forms.

 

HI97715 FEATURES/BENEFITS:

Stable Light Source:

  • The internal reference system of the HI97715 photometer compensates for any drifts due to power fluctuations or ambient temperature changes. With a stable source of light the readings are fast and stable between your blank (zero) measurement and sample measurement..

High Efficiency Light Source:

  • LED light sources offer superior performance compared to tungsten lamps. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce little heat, which could otherwise affect electronic stability. 

High Quality Filters:

  • Improved optical filters ensure greater wavelength accuracy and allow a brighter, stronger signal to be received. The end result is higher measurement stability and less wavelength error.

Greater Light Yield:

  • A focusing lens collects all of the light that exits the cuvette, eliminating errors from imperfections and scratches that may be present in the glass. The use of the convex lens reduces the need for indexing cuvettes..

CAL Check Functionality:

  • Hanna’s exclusive CAL Check feature allows for performance verification and calibration of the meter using NIST traceable standards. Our CAL Check standard vials are developed to simulate a specific absorbance value at each wavelength to verify the accuracy of subsequent readings.

Mulitple Measurement Methods:

  • Users can select the use of powder reagents supplied in packets or the use of low cost liquid reagents supplied in a dropper bottle.

Built-in Reaction Timer:

  • Waiting the proper reaction time is of key importance when performing colorimetric measurements. The countdown timer displays the time remaining until a measurement will be taken, ensuring consistent results between sample measurements and users.

Large Cuvette Size:

  • The sample cell of the HI97715 fits a round, glass cuvette with a 25 mm path length. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.

Intuitive Dot Matrix Display:

  • The HI97715 is designed with a backlit, graphic LCD. With virtual keys, a battery status indicator, and error messages. Users will find the meter interface intuitive and easy to read. A dedicated help key provides information relating to the current meter operation, and can be used at any stage in the setup or measurement process to show contextual help.

Auto-off Protection:

  • The meter uses three common AA batteries that allow for about 800 measurements to be taken. The auto-off feature automatically shuts off the meter after 15 minutes of inactivity in order conserve battery life.

 

Ammonia Range 0.00 to 10.00 mg/L (as NH3-N)
Ammonia Resolution 0.01 mg/L
Ammonia Accuracy ±0.04 mg/l ±4% of reading
Ammonia Method Adaptation of the ASTM Manual of Water and Environmental Technology, D1426 Nessler method
Photometer/Colorimeter Light Source Light emitting diode
Photometer/Colorimeter Light Detector silicon photocell with narrow band interference filter @ 420 nm
Bandpass Filter Bandwidth 8 nm
Bandpass Filter Wavelength Accuracy ±1.0 nm
Cuvette Type round, 24.6 mm diameter (22 mm inside)
GLP date, time of last calibration
Display 128 x 64 pixel B/W LCD with backlight
Logging Type automatic logging
Logging Memory 50 measurement
Battery Type/Life 1.5V AA battery (3 pcs.) / > 800 measurements (without backlight)
Automatic Shut-Off After 15 minutes of inactivity (30 minutes before a READ measurement)
Environment 0 to 50°C (32 to 122°F); relative humidity: 100% (IP67)
Weight 380 g (13.4 oz.) with batteries
Dimensions 142.5 x 102.5 x 50.5 mm (5.6 x 4.0 x 2.0″)
Ordering Information HI97715C is supplied with CAL-Check standards, cuvettes (2), caps (2), plastic inserts for cuvette, (2), scissors, cuvette cleaning cloth, 1.5V AA batteries (3), instruction manual, and instrument quality certificate.

 