[:lt]Kalcio kietumo nešiojamas fotometras - HI96720C rinkinys[:en]Calcium Hardness Portable Photometer - HI96720C[:] — Calcium Hardness Portable Photometer - HI96720C [:lt]Magnio kietumo nešiojamas fotometras - HI96719[:en]Magnesium Hardness Portable Photometer - HI96719[:] Magnesium Hardness Portable Photometer - HI96719 —

Magnesium Hardness Portable Photometer – HI96719C

391.00  + PVM

The HI96719 Magnesium Hardness Portable Photometer combines accuracy and ease of use in an ergonomic, portable design. 

SKU: HI96719 C Category:

Out of stock

This photometer is not produced anymore. HI96719C was changed into new series advanced optical system photometer HI97719C.

 

The HI96719 Magnesium Hardness Portable Photometer combines accuracy and ease of use in an ergonomic, portable design. A user can accurately determine the concentration of magnesium hardness within a 0.00 to 2.00 mg/L (ppm) range using the HI93719-0 ready made reagents. The HI96719 offers many advanced features including the exclusive CAL Check function used for performance verification and calibration of the meter.

CAL Check Validation and Calibration

Built-in Timer

Automatic Shut Off

 

Details

The HI96719 portable photometer is for the measurement of magnesium hardness. Hanna’s portable photometers feature an advanced optical system; the combination of a special tungsten lamp, a narrow band interference filter, and silicon photodetector ensure accurate photometric readings every time. The Hanna exclusive CAL Check feature utilizes ready-made, NIST traceable standards to verify both meter validation and calibration. The exclusive cuvette locking system ensures that the cuvette is inserted into the measurement cell in the same position every time to maintain a consistent path length.

Features at-a-glance

CAL Check – Allows for performance verification and calibration of the meter using a CAL Check NIST traceable secondary standard.

GLP – Records the date of the last user calibration performed.

Built in timer – Allows the use of a timer to ensure the appropriate 3 minutes and 30 seconds reaction time is used for the chemical reaction. At the end of the timer countdown the meter will automatically take the reading. This feature ensures consistency across multiple users.

Indexing indent on meter – The meter has an indent that allows for a lock and key fit with the cuvette cap. This ensures that the cuvette is indexed consistently (same position) in order to maintain the same path length for accurate results.

Cooling Lamp Indicator – It is necessary to maintain a consistent temperature of the optical components in order to maintain a narrow wavelength band of light. This photometer has a cooling lamp indicator that is displayed for a short period of time before each measurement in order to allow the components to cool and obtain the highest accuracy possible.

Error messages – Messages on display alerting to problems including no cap, over range and under range readings, and light source error.

Auto-shut off – Automatic shut off after 10 minutes of non-use when the meter is in measurement mode. Prevents wastage of batteries in the event the meter is accidentally not turned off.

Battery status indicator

The instrument has a battery level indicator to display reaming life as follows:

• 3 lines for 100 % capacity

• 2 lines for 66 % capacity

• 1 line for 33 % capacity

• Battery icon blinks when the capacity is less than 10 %.

Units of measure – Appropriate unit of measure is displayed along with reading.

 

 

Significance of use

Water, with exception to distilled water, contains dissolved salts (magnesium and calcium carbonates). The concentration of these salts determines the water hardness, which can be expressed in calcium carbonate or magnesium carbonate. The sum of these two represents the total hardness level. In addition, water hardness is also related to the phenomenon of pipe rusting in water heating and cooling systems, reverse osmosis, and demineralization plants.

The HI96719 uses an adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, EDTA colorimetric method to measure magnesium hardness concentrations of less than 2.00 mg/L (ppm). When the reagent is added to samples containing magnesium salts, the the sample will turn a violet hue; the greater the concentration, the deeper the color. The associated color change is then colorimetrically analyzed according to the Beer-Lambert Law. This principle states that light is absorbed by a complementary color, and the emitted radiation is dependent upon concentration. For magnesium hardness determination, a narrow band interference filter at 525 nm (green) allows only green light to be detected by the silicon photodetector and omits all other visible light emitted from the tungsten lamp. As the change in color of the reacted sample increases, absorbance of the specific wavelength of light also increases, while transmittance decreases.

 

The HI96719 is available as a kit (HI96719C) which includes:

  • Portable photometer
  • Sample cuvettes (2)
  • Caps
  • CAL Check standards with certificate
  • 1mL syringe with tip
  • Scissors
  • Cuvette cleaning cloth
  • Rugged carrying case
    • Carry case has thermoformed insert for meter and accessories

*Reagents ordered separately

 

CAL Check™ standards with certificate

The HI96719-11 CAL Check standards are used for calibration and performance verification of photometers with the CAL Check function.

Supplied with Certificate of Analysis

  • Lot number
  • Expiration date
  • Standard value @ 25 °C
  • Reference meter NIST traceable

Provided storage containers

  • Light tight
  • Protects from accidental breakage
 
Hardness, Magnesium Range 0.00 to 2.00 mg/L (ppm)
Hardness, Magnesium Resolution 0.01 mg/L
Hardness, Magnesium Accuracy ±0.11 mg/L ±5% of reading
Hardness, Magnesium Method adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th ed. EDTA colorimetric method
Photometer/Colorimeter Light Source tungsten lamp
Photometer/Colorimeter Light Detector silicon photocell with narrow band interference filter @ 525 nm
Battery Type/Life 9V battery
Automatic Shut-Off after ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder
Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing
Weight 360g (12.7oz.)
Dimensions 193 x 104 x 69 mm (7.6 x 4.1 x 2.7”)
Ordering Information HI96719 is supplied with sample cuvettes (2) with caps, 9V battery, instrument quality certificate and instruction manual. CAL Check™ standards and testing reagents sold separately.

 