[:lt]HI94754A-25 Reagentai - COD mažo diapazono EPA patvirtintas dichromato metodas[:en]HI94754A-25 COD Low Range EPA Approved Dichromate Method[:] — HI94754A-25 COD Low Range EPA Approved Dichromate Method [:lt]HI3874-100 Pakaitinių reagentų rinkinys nitratams, 100 testų[:en]HI3874-100 Replacement Reagents Nitrate[:] HI3874-100 Replacement Reagents Nitrate —

HI93754H-25 COD certified reagents LR compatible

64.00  + PVM

This method with chromium-sulphuric acid is officially recognised by EPA for wastewater analysis

SKU: HI93754H-25 Category:

Available on backorder - This item may take 2-3 weeks to deliver.

The HI93754H-25 is a box of 25 reagent vials for COD, low range.

*This method with chromium-sulphuric acid is officially recognised by EPA for wastewater analysis.

Each box of 25 vials is supplied with a Hanna certificate of quality. The reagents are traceable to NIST SRM® 930.

Hanna offers reagents to cover three separate ranges.

  • Three measurement ranges to satisfy every need – As COD levels vary depending on the application and process measuring points. Simply choose the best range for the application: low range – 0 to 150 mg/L O2, medium range – 0 to 1500 mg/L O2 and high range: 0 to 15000 mg/L O2.
  • Accurate and repeatable measurements – Hanna COD reagents have been developed in accordance with Standard Methods 5220D, USEPA 410.4 and ISO 15705:2002 methods.
  • Pre-dosed vials – Hanna vials contain approximately 3mL of pre-dosed reagent. The operator just needs to add a small quantity of the sample.
  • Quick and accurate measurements – With pre-dosed vials, test preparation time is dramatically reduced. There is no time-consuming reagent preparation procedure or glassware cleaning.
  • Safe reagents – Hanna COD reagents are safe for operators and the environment. Vials and caps have been designed to avoid accidental reagent spills. Due to the pre-dosed reagents, the amount of chemicals and handling time is minimised.

 

About the testing methods

  • Dichromate EPA – Method with chromium-sulphuric acid is officially recognised by EPA for wastewater analysis.
  • Dichromate mercury-free – This method is recommended for general purpose analysis with no chloride interference.
  • Dichromate ISO – Method follows the official method ISO 15705. COD MR ISO method is 0 – 1000 mg/L. Meter can read higher.
Range   0 to 150 mg/L (ppm)
Dichromate EPA Method    
COD – LR    
 Range (as O2)   0 to 150 mg/L
 Resolution   1mg/L
 Accuracy   ±5 mg/L ±5% of reading
 Pack of 25 vials   HI-93754A-25
 Replacement reagents   HI-94754A-25
COD – MR    
 Range (as O2)   0 to 1500 mg/L
 Resolution   1mg/L
 Accuracy   ±15 mg/L ±4% of reading
 Pack of 25 vials   HI-93754B-25
 Replacement reagents   HI-94754B-25
Dichromate Method    
COD – HR    
 Range (as O2)   0 to 15000 mg/L
 Resolution   10mg/L
 Accuracy   ±150 mg/L ±3% of reading
 Pack of 25 vials   HI-93754C-25
 Replacement reagents   HI-94754C-25
Dichromate Mercury-Free Method    
COD – LR    
 Range (as O2)   0 to 150 mg/L
 Resolution   1mg/L
 Accuracy   ±5 mg/L ±5% of reading
 Pack of 25 vials   HI-93754D-25
 Replacement reagents   HI-94754D-25
COD – MR    
 Range (as O2)   0 to 1500 mg/L
 Resolution   1mg/L
 Accuracy   ±15 mg/L ±4% of reading
 Pack of 25 vials   HI-93754E-25
 Replacement reagents   HI-94754E-25
Dichromate ISO Method    
COD – LR    
 Range (as O2)   0 to 150 mg/L
 Resolution   1mg/L
 Accuracy   ±5 mg/L ±5% of reading
 Pack of 25 vials   HI-93754F-25
 Replacement reagents   HI-94754F-25
COD – MR    
 Range (as O2)   0 to 1500 mg/L
 Resolution   1mg/L
 Accuracy   ±15 mg/L ±4% of reading
 Pack of 25 vials   HI-93754G-25
 Replacement reagents   HI-94754G-25