[:lt]Checktemp® Skaitmeninis termometras - HI98501[:en]Checktemp® Digital Thermometer - HI98501[:] — Checktemp® Digital Thermometer - HI98501 [:lt]AmpHel® pH elektrodas su stirpintuvu[:en]AmpHel® pH electrode with internal battery- HI2911B/5[:] AmpHel® pH electrode with internal battery- HI2911B/5 —

Refillable pH Electrode for fluoride applications – HI1144B

289.25 € + PVM

Fluoridhaltige Proben (max. 2 g/l bei pH 2 und Temperatur <60°C)

SKU: HI1143B Category:

Available on backorder - This item may take 2-3 weeks to deliver.

The HI1143B is a glass body, refillable, single junction pH electrode with a BNC connector for fluoride applications. This electrode has a single ceramic junction in the outer reference cell and the spherical pH sensing portion is made with high temperature glass for  hyfdrofluoric acid resistant.

Details

Hanna Instruments offers a wide variety of pH electrodes that are designed for many different applications. The type of glass used for sensing pH, bulb shape, body material, type of junction, type of reference and electrolyte used are just some of the design considerations.

 

 

HT Glass

High Temperature Glass Formulation

The measurement of pH at very high temperatures is detrimental to the sensitive glass bulb and will shorten the life of it. A pH electrode with general purpose (GP) glass will have a resistance of 100 megaohms at 25°C while the resistance of HT glass is around 400 megaohms at 25°C. As the HI1144B is used at elevated temperatures the resistance decreases to approach the that of GP glass. The HI1144B is suitable to use with samples that measure from 0 to 100°C.

spherical bulb

Spherical Bulb

The spherical bulb is for general purpose use. Other tip shapes include conic for penetration and flat tip for surface measurements.

glass electrode body

Glass Body

The glass body is ideal for laboratory use. The glass is resistant to many harsh chemicals and is easily cleaned. The glass body also allows for a fast transfer of heat to the internal reference electrolyte. The mV generated by the reference cell is temperature dependent. The faster the electrode reaches equilibrium, the steadier the reference potential.

 

Double Ceramic Outer Junction

The HI1144B is a single junction design. The junction also known as a salt bridge is necessary component of the electrical circuit. The movement of ions must flow through the junction for a steady reading. The outer reference has a single ceramic frit. The ceramic is a porous material that is easily fused with the glass body and has a similar expansion coefficient. A single ceramic junction has a flow rate of 15-20 μL/hour. Other junction types are available with higher flow rates and made with different materials.  

 

Refillable

Refillable

The HI1144B is a refillable probe. Since it is a double junction pH electrode the fill solution is the HI7082 3.5M KCl. This solution does not contain any silver as with single junction electrode. The absence of silver will prevent any silver precipitate from forming at the junction surface and clogging it. Clogging of the junction will result in drifty and erratic readings.

 

BNC

BNC Connector

The HI1144B uses a BNC connector. This type of connector is universal in that it can be used on any pH meter that has the female BNC probe input. Other type of connectors include DIN, screw type, T-type, and 3.5mm to name a few. These types of connectors tend to be proprietary for a particular type of meter and are not interchangeable.

 

Measurement Range pH: 0 to 10
Reference Cell Type double, ag/HAgCl
Junction Type/Flow Rate ceramic, single / 15-20 μL/h
Refill Electrolyte 3.5M KCl
Body Material glass
Tip / Shape spheric (dia: 9.5 mm)
Matching Pin no
Max. Pressure 0.1 bar
Temperature Operating Range -5 to 60°C – HF
Body Length/Overall Length 120 mm / 175.5 mm
Temperature Sensor no
Outer Diameter 12 mm
Cable coaxial; 1 m (3.3’)
Connector Type BNC
Amplifier no
Recommended Use  samples with fluoride max 2 g/L at pH 2 and temperature <60°C.

Additional information

Weight 0.101 kg

Related products