[:lt]Platininis ORP pusės elemento elektrodas su BNC jungtimi - HI3133B[:en]Platinum ORP Half-Cell Electrode with BNC Connector - HI3133B[:] — Platinum ORP Half-Cell Electrode with BNC Connector - HI3133B [:lt]Geliu užpildytas ORP elektrodas su auksiniu kontaktu ir BNC jungtimi - HI4430B[:en]Gel Filled ORP Electrode with Gold Contact and BNC Connector - HI4430B[:] Gel Filled ORP Electrode with Gold Contact and BNC Connector - HI4430B —

ORP electrode; Use for laboratory general purposes, DIN connector recommended for HI98140, HI98150, HI98230, HI98240 pH meters

224.00 € + PVM

Intelligente Redox Elektrode aus Robustem PEI mit einfachem Diaphragma, Schwimmbad, Outdoor-Anwendungen.

SKU: HI3619D Category:

Available on backorder - This item may take 2-3 weeks to deliver.

The HI3618D is a glass body, refillable, single junction ORP electrode with a DIN connector. This electrode has a single ceramic junction in the outer reference cell and the ORP sensing pin is made with platinum.

This design consideration is ideal for laboratories and general purpose ORP measurements.

temperature sensor

Built-In Temperature Sensor

 

refillable electrode

Refillable Electrode

The HI3618B is a refillable probe. Since it is a single junction ORP electrode the fill solution is the HI7071 3.5M KCl + AgCl. If using a refillable ORP electrode, the fill cap should be removed prior to measurement. Removing the cap creates positive head pressure in the reference cell allowing for higher flow rate of electrolyte through the outer junction. A higher flow rate will result in a faster and more stable reading.

Glass Body

Glass body

The glass body is ideal for laboratory use. The glass is resistant to many harsh chemicals and is easily cleaned. The glass body also allows for a fast transfer of heat to the internal reference electrolyte. The mV generated by the reference cell is temperature dependent. The faster the electrode reaches equilibrium, the steadier the reference potential.

Ceramic Junction

Single Ceramic Junction

The outer junction of an electrode, also known as a salt bridge, is necessary component of the electrical circuit. The movement of ions must flow through the junction for a steady reading. The outer reference has a single ceramic frit. The ceramic is a porous material that is easily fused with the glass body and has a similar expansion coefficient. A single ceramic junction has a flow rate of 15-20 μL/hour. Other junction types are available with higher flow rates and made with different materials.

 

 

platinum sensing pin

Platinum Sensing Pin

The HI3618D ORP sensor is made with platinum. An ORP sensor must be chemically inert; it cannot be oxidized or reduced itself. It must also have the proper surface characteristics to promote rapid electron  exchange, a property known as high exchange current density. Two noble metals have proven to work well for this purpose: pure platinum and pure gold are both used in the construction of ORP sensors. The platinum sensor is often preferred because it is mechanically simpler and safer to produce. Platinum can be welded to glass and has the same thermal coefficient. The platinum sensor signal is carried through the electrode body, and together with the reference signal is conducted to the measurement meter.

DIN connector

DIN Connector

The HI3618D uses a DIN connector. This type of connector is generally proprietary to the meters they are supplied with and may not be interchangeable. Other type of connectors include BNC, screw type, T-type, and 3.5mm to name a few. The HI3618D ORP probe is used witht eh HI8314 portable meter.

ORP Sensing Type Platinum
Measurement Range ORP: ±2000 mV
Reference Cell Type single, Ag/AgCl
Junction Type/Flow Rate ceramic, single / 15-20 μL/h
Refill Electrolyte 3.5M KCl + AgCl
Body Material glass
Tip / Shape platinum pin
Matching Pin no
Max. Pressure 0.1 bar
Temperature Operating Range -5 to 70°C (23 to 158°F)
Body Length/Overall Length 120 mm / 175.5 mm
Temperature Sensor yes
Outer Diameter 12 mm
Cable 5-pole; 1 m (3.3′)
Connector Type DIN
Amplifier yes
Recommended Use laboratory general purpose

Additional information