[:lt]HI38434 – Pool Line balinimo testų rinkinys[:en]HI38434 – Pool Line Bleach Test Kit[:] — HI38434 – Pool Line Bleach Test Kit [:lt]Baseino ir SPA kontroleris be analoginės išvesties - BL120-10[:en]Swimming Pool & Spa Controller without Analog Output - BL120-10[:] Swimming Pool & Spa Controller without Analog Output - BL120-10 —

pH and ORP Controller with ethernet for remote cloud monitoring – BL122

1,485.00  + PVM

pH and ORP Controller with ethernet for remote cloud monitoring
SKU: BL122-10 Categories: , Tag:

Available on backorder - This item may take 2-3 weeks to deliver.

Designed to maintain constant pH and disinfectant levels in swimming pools, hot tubs, and spas, the BL122, and BL123 pH and ORP controller offers the added benefit of allowing remote connection and access to devices via the Hanna Cloud web app.

  • Keep track from anywhere with Hanna Cloud connectivity.
  • Inline or panel mounted models.
  • Built-in datalogger for compliance monitoring

Peristaltic Chemical Feed Pumps

Equipped with two peristaltic dosing pumps with replaceable chemical resistant tubing that are proportionally controlled with adjustable flow rates.

Automatic Proportional Pump Control

Adjust the proportional band based on the sensitivity of your process to chemical addition, finetuning the amount of time that the pumps are dosing.

Adjustable Flow Rate

The dosing pump flow rate is adjustable from 0.5 to 3.5L/h, allowing for better control in maintaining a desired set point.

Connectivity

Transfer data to a PC using a flash drive and the USB port or connect via the Ethernet Port to the Hanna Cloud.

Hold Input

Connect a flow switch so that when there is no flow or no power applied to the recirculation pump, the hold circuit will disable the dosing pumps to prevent any dosing when there is no movement of water in the system.

BL123 Analog Outputs

The BL123 pH and ORP controller offers three 4-20 mA outputs that can be disabled or connected to an external recording device. Each of the three measured parameters (pH, ORP, and temperature) can be assigned to an analog output.

 


Programmable Alarm System

  • Set low and high alarm levels for all parameters. When an alarm is activated, all dosing will stop to prevent overdosing.

 


Automatic Logging

  • Readings are automatically logged every 10 seconds. Logged data includes pH, ORP, and temperature values, last calibration data, setup configuration, and any event data.

 


GLP

  • GLP stores pH/ORP calibration information including date and time for pH/ORP sensors.

 


Password Protected

  • Password protection restricts access to calibration, setup, and review of logged data for increased security.

 


3 Display Modes

  • The LCD can display all 3 parameters at one time, a 3-second cycle of single parameters, or a real-time graph.

 

Keep Track Anywhere with Hanna Cloud Connectivity

Hanna Cloud is a web-based application that connects you to measurement devices such as the BL122 and BL123. Measurements and data storage are accessible from your PC, tablet or phone. Measurements, trends, history, device settings, alarms, and messages are transmitted to your “Dashboard” as your instrument measures and controls your process.

Features

Measurement & Graphing

    • Measurement, alarm, hold and pump status are easily viewable. Use a graph to view trends over the last 12 hours or change the time period. Log history can be transferred as a PDF or .CSV.

Good Laboratory Practices (GLP)

    • Good Laboratory Practice (GLP) refers to a quality control function used to ensure uniformity of probe calibrations and measurements. GLP data is readily available for increased traceability. 

Notifications

    • Select which notifications you would like to receive. Multiple secondary users may also be added to your device account to monitor measurements and receive email or pop-up messages from your process device. 

pH Specifications

pH Range 0.00 to 14.00 pH
pH Resolution 0.01 pH
pH Accuracy ±0.05 pH
pH Calibration pH buffer calibration: automatic, two-point (4.01, 7.01, 10.01 pH)
pH process calibration: single point, adjustable
pH Controller proportional feed using adjustable set point and adjustable proportional band
delay to start at power-on
overdosing protection using overfeed safety timer

mV Specifications

mV Range ±2000 mV
mV Resolution 1 mV
mV Accuracy ±5 mV
ORP (mV) Calibration single point, adjustable
ORP Controller proportional feed using adjustable set point and adjustable proportional band
delay to start at power-on
overdosing protection using overfeed safety timer
pH regulator interlocked

Temperature Specifications

Temperature Range -5.0 to 105°C (23.0 to 221.0°F)
Temperature Resolution 0.1°C (0.1°F)
Temperature Accuracy ±1°C (±1.8°F)
Temperature Compensation automatic -5.0 to 105°C (23.0 to 221.0°F) for pH

Additional Specifications

Alarms high and low with enable/disable option for all parameters
alarm is triggered when 5 consecutive readings are over/under threshold
Log Feature automatic log
60 days logging with 10 seconds period (or 100 logs)
pH/ORP/temperature measurements
events: alarms/errors/power outage
recall table/graphic modes
export on USB key
log files in CSV format
Cloud Connectivity BL122 and BL123 devices are connected to Hanna Cloud using a secured connection.

  • ethernet (RJ45) 10/100 Mbps connection
  • device Identity Registry
  • policy-based authorization of security keys

The instrument will send status information to Hanna Cloud with a defined period

  • readings: pH, ORP, temperature
  • events: alarms/warnings/errors
  • peripheral status: LEDs
  • last dosed acid and clorine volumes
  • GLP info

The instrument will send setup information to Hanna Cloud at startup and whenever the setup is changed on the instrument.

  • alarm settings
  • dosing settings
  • general settings
  • system: meter information (model, FW version, OS version, serial number), probe information (type, FW version, serial number)

The BL122 and BL123 “Remote Hold” mode:

  • is an emergency mode that can be remotely triggered via web application
  • in this mode the pumps are deactivated
  • can be canceled manually from the controller menu
Ethernet Input ethernet connector (RJ-45) 10/100 Mbps connection
Pump Control  pump flow control 0.5 to 3.5 L/h (0.13 to 0.92 G/h) and maximum output pressure 1 atm (14 psi) manual control for each pump
Password Protection setup, calibration and log recall features are password protected
Storage Interface USB
GLP pH/ORP
Alarm System Intuitive alert system based on LED color coded alarm system
Alarm filtering options
Alarm relay control based on user setup filters
Alarm Relay Output (1) SPDT 5A/230 VAC
Activated by selectable pH/ORP/Temperature alarm conditions
Analog Outputs (3) (BL123 only) three configurable analog outputs, 4 to 20 mA, sourcing
output impedance ≤500Ω
accuracy <0.5 % FS
galvanic isolation, up to 50 V relative to earth
Digital Inputs (3) galvanic isolated, powered contact type
one input for low level in acid / base tank (contact open)
one input for low level in chlorine tank (contact open)
one input for Hold mode (contact open)
Probe Input (1) probe type: HI1036-18XX pH/ORP/Temperature/Matching pin, combined digital probe
DIN waterproof connector
galvanic isolation
RS485 interface
Power Supply 100-240 VAC
Power Consumption 15 VA
Environment 0 to 50°C (32-122°F), max. 95% RH non-condensing
Dimensions 245 x 188 x 55 mm  (73 mm with pumps); 9.6 x 7.4 x 2.2” (2.9″ with pumps)
Weight 1700 g (60 oz.)
Casing wall mounted, built-in pump, IP65 rated
Ordering Information
In-Line Configuration:

BL122-10 and BL123-10 (analog outputs) pH/ORP/temperature pool controller is supplied with HI1036-1802 pH/ORP/temperature digital probe with matching pin, saddle for electrode 50 mm (1), fittings for electrode injector (2), saddle for injectors 50 mm (2), peristaltic pump tubing (2), aspiration (5 m) and injection (5 m) tubing, aspiration filter (2), pH 7.01 buffer sachets, 20 ml (3), pH 4.01 buffer sachets, 20 ml (3), 470 mV ORP test solution sachet, 20 ml (3), power cable, user manual, and quality certificates for meter and probe. 

User Panel Flow Cell Configuration:

BL122-20 and BL123-20 (analog outputs) pH/ORP/temperature pool controller is supplied with HI1036-1802 pH/ORP/temperature digital probe with matching pin, two valves for flow-cell connections with fittings and tubing 10 m, saddle for valves 50 mm (2), saddle for electrode 50 mm (1), fittings for electrode injector (2), saddle for injectors 50 mm (2), peristaltic pump tubing (2), aspiration (5 m) and injection (5 m) tubing, aspiration filter (2), pH 7.01 buffer sachets, 20 ml (3), pH 4.01 buffer sachets, 20 ml (3), 470 mV ORP test solution sachet, 20 ml (3), power cable, user manual, and quality certificates for meter and probe. 


Related products