[:lt]HI76410/4 Galvaninis DO daviklis HI8410 kontroleriui, 4 M laidas[:en]HI76410/4 GALVANIC DO PROBE FOR HI-8410 PROCESS, 4 M CABLE[:] — HI76410/4 GALVANIC DO PROBE FOR HI-8410 PROCESS, 4 M CABLE [:lt]Amoniako ISE kondicionavimo tirpalas - HI4001-45[:en]Conditioning Solution for Ammonia ISE - HI4001-45[:] Conditioning Solution for Ammonia ISE - HI4001-45 —

HI-8410 PANEL MOUNTED DISSOLVED OXYGEN CONTROLLER

830.00  + PVM

HI8410 PANEL MOUNTED DISSOLVED OXYGEN CONTROLLER

SKU: HI8410 Categories: ,

Available on backorder - This item may take 2-3 weeks to deliver.

The HI 8410 is an extended range panel mounted Dissolved Oxygen (DO) controller that is used to maintain and monitor the concentration of DO in a wide range of applications from wastewater treatment to aquaculture.

 

The HI-8410 is an extended range panel mounted Dissolved Oxygen (DO) controller that is used to maintain and monitor the concentration of DO in a wide range of applications from wastewater treatment to aquaculture. The HI 8410 uses a Galvanic probe and typically require less maintenance than a Polarographic style making it ideal for long term monitoring of aeration basins, ponds, and lakes.

The set point for controlling the activation of the relay is adjusted manually by the user. An alarm relay is also manually adjustable and is based upon a tolerance from the programmed set point. Calibration is single set point and can be done in zero oxygen solution.

The dosage mode: Automatic, Continuous ON or OFF and over dose control by setting the Overtime dosage trimmer. If the dosing relay remains continuously activated for more than the selected dosing time, the alarm relay is activated, the alarm LED will start blinking and the dosing relay will be deactivated. A jumper found on the rear panel can disable the “Over time dosage” function.

Range   0.0 to 50.0 mg/L (ppm) O2
0 to 600 % O2
-5.0 to 50.0 °C
Resolution   0.1 mg/L or 1% ( O2) / 0.1 °C
Accuracy   ±1% of reading ( O2) / ±0.2 °C
Input   High impedance 1012 Ohm; Reference annd Matching pin inputs are available; 4-20 mA
Calibration   Manual, one point, in saturated air
Temperature Compensation   Automatic, from -5 to 50 °C (23 to 122 °F)
Salinity Compensation   0 to 51 g/L (resolution 1 g/L)
Probe (not included)   HI 76409/4 with 4 m cable or HI 76409/10 with 10 m cable
Recorder Output   0 to 20 mA or 4 to 20 mA (isolated)
Setpoint and Alarm Relay   1, isolated, 2A, Max. 240V, resistive load, 1,000,000 strokes
Setpoint Range   1 to 600 % O2;0.1 to 50.0 mg/L (ppm) O2
Alarm Range   1.0 to 5.0 mg/L (ppm) O2
Hysteresis Range   0.1 to 1.0 mg/L (ppm) O2
Dosing Control   OFF/AUTO/ON with selection switch
over Dosing Control   Adjustable, from 5 min to 60 min with knob or Disable by wire strap – on rear panel
Backlight   Continuous ON
Power Supply   115 Vac ±10% or 230 Vac ±10%; 50/60 Hz
Enclosure   Black anodized aluminum body; front-panel with flame retardant ABS; transparent splash-proof front cover
Environment   -10 to 50°C (14 to 122°F); RH max 95% non-condensing
Panel Cutout   141 x 69 mm (5.6 x 2.7″)
Weight   1 kg (2.2 lb.)
 