The HI904 Karl Fischer (KF) Coulometric Titrator is an automatic titrator that complements our wide range of products dedicated to efficient and accurate laboratory analysis. The HI904 analyzes for water content ranging from 1 ppm to 5%. This powerful titrator effectively monitors the KF reaction, detects the endpoint, and performs all necessary calculations and graphing.
Coulometric reagent system
Precision iodine generation
Hanna’s dosing algorithm allows for an extremely small amount of iodine necessary for the Karl Fischer reaction to be generated electrolytically using a pulsed current up to 400 mA delivering titrant accurately and precisely.
Titration and solvent system
Chemically resistant titration vessel and tubing
The glass titration cell and PTFE tubing is designed to withstand the harsh solvents and reagents involved in Karl Fischer reactions.
Sealed solvent system
Ground glass joints completely seal the glass titration cell minimizing exposure to ambient humidity, keeping the system dry, and reducing reagent consumption while saving time between titrations. Solvent may be exchanged in a matter of seconds with a quick fitting adjustment.
Molecular sieve desiccant
High efficiency molecular sieve desiccant helps maintain low and stable drift rates within the titration cell while preventing the ingress of ambient humidity into the sealed solvent system.
Built-in stirrer
Automatic, integrated magnetic stirrer adjustable from 200-2000 RPM with optical feedback for automatic speed control.
Titrator capabilities
Dynamic titrant dosing
The titration speed feature allows for timely and accurate titration results by relating the amount of iodine generated to the mV response from the Karl Fischer reaction.
Drift rate compensation
The HI904 automatically adjusts the titration calculation to account for the effects of any ambient humidity entering the titration cell. This provides a more accurate result by correcting for water not present in the actual sample.
Titration results averaging
Successive results from a titration method may be averaged with recording of the standard deviation.
Titration reports
Titration results can be viewed on-screen or transferred to a USB storage device
Selectable endpoint criteria
The HI904 employs a dual platinum pin electrode for bivoltammetric endpoint determination. Users may choose termination criteria based on mV stability times or drift rates.
Multistage cell preparation
A pre-titration stage eliminates residual water present in the solvent and the cell, providing a reliable baseline start to analysis. Standby mode then keeps the solvent dry between titrations and when the titrator is not in use.
Interface & display
Interactive color display
A large, color LCD screen clearly shows the chosen titration method along with results, units, drift rate, and mV value. Titration results are displayed with options to average results or a user-customized report
Sample analysis
Interface displays real-time monitoring of water content and results.
Detailed titration graphs
A real-time titration curve can be displayed during each titration; this feature is useful when new methods are tested or when a procedure requires optimization.
Simple and quick navigation
Virtual key selections present on the display allow for simple and quick navigation between screens and menus without getting lost in a nest of information.
Customizable general options
Titration general options can be configured to user requirements
Configurable balance interface
Sample size may be automatically entered from any laboratory analytical balance with a RS232 serial output saving time and labor.
Data & storage
Customizable titration reports
Each titration report is fully customizable so users can ensure they are storing and filing the appropriate data required for their application and procedures.
Flexible GLP management
HI900 Series titration systems can be easily incorporated into any existing GLP data management program. All necessary GLP (Good Laboratory Practice) information can be recorded with each sample including: sample identification, company and operator name, date, time, electrode ID codes, and calibration information.
Effortless data transfer
Data can easily be transferred to a USB flash drive or PC with the Hanna HI900PC application software. The USB port allows for the transfer of titration methods, titration reports, and software upgrades via USB flash drive.
Methods of analysis
Customizable methods
The HI904 can store up to 100 user-defined or standard titration methods. Each method may be customized and optimized for performance based on application and user requirements.
Titration method support
Onsite installation, training, and customization is available from one of our Applications or Service experts. Hanna offers continued support via phone or webinar for any questions you might have along the way.
Sample addition
HI904 recommends a sample size based on expected results.
Adaptable standard methods
Our technical experts can program and customize standard methods developed by such affiliations as ISO, ASTM, AOAC, AOCS, EPA, and more directly onto your titrator. Ask our Sales Consultants which standard methods are possible with our HI904 Karl Fischer system.
Connectivity and functionality
Multiple peripherals
Users can print reports directly from the titrator using a standard parallel printer. An external monitor and keyboard may be attached for added versatility, as well as an analytical balance for automatic sample mass entry for titrations.
Specifications
|
Titration
|
Range | 1 ppm to 5% |
| Resolution | 0.1ppm to 0.0001% | |
| Result units | %, ppm, ppt, mg/g, μg/g, mg, μg, mg/mL, μg/mL, mg Br/100g, g Br/100g, mg Br, g Br | |
| Sample type | Liquid or solid (external dissolution / extraction) | |
| Titration vessel | Operating volume between 100 – 200 mL | |
| Reagent handling system | Sealed system with integrated diaphragm air pump and beaker adapter | |
|
Generator electrode
|
Configuration | Diaphragm or diaphragm-less |
| Current control | Automatic or fixed (400 mA) | |
| Electrode type detection | Automatic | |
|
Determination
|
Pre titration conditioning | Automatic |
| Background drift correction | Automatic or user-selectable value | |
| Endpoint criteria | Fixed mV persistence, relative drift stop, or absolute drift stop | |
| Dosing | Dynamic | |
| Result statistic | Mean, standard deviation | |
|
Detector electrode
|
Type / connection | Dual platinum pin, polarization electrode / BNC connector |
| Polarization Current | 1, 2, 5, or 10 μA | |
| Voltage range | 2 mV to 1100 mV | |
| Voltage resolution | 0.1 mV | |
| Accuracy (@25°C/77°F) | ±0.1% | |
|
Peripheral devices
|
PC | Easily view, transfer, print or delete methods and reports via HI900 PC application |
| USB flash drive | Easily upgrade software or transfer methods and reports between devices using a USB drive | |
| Laboratory analytical balance | RS232 to connect a laboratory analytical balance | |
| Printer | Print directly from the HI904 to a parallel port printer | |
| Monitor | Instrument status and titrations can be viewed on a larger screen using any VGA compatible external monitor | |
| Keyboard | Alphanumeric text can be entered using an optional PS/2 keyboard | |
|
Additional specifications
|
Graphic display | 5.7” (320 x 240 pixel) color LCD |
| Titration methods | Up to 100 (standard and user methods) | |
| Data storage | Up to 100 (titration and drift rate reports) | |
| GLP conformity | Good Laboratory Practice and instrument data storage and printing | |
| Languages | English, Portuguese, Spanish, and French | |
| Enclosure material | ABS plastic and steel | |
| Keypad | Polycarbonate | |
| Power | 100-240 VAC “-01” models, US plug (type A) “-02” models, European plug (type C) |
|
| Operating environment | 10 to 40 °C, up to 95% RH | |
| Storage environment | -20 to 70 °C, up to 95% RH | |
| Dimensions / weight | 390 x 350 x 380 mm (15.3 x 13.8 x 14.9”); approximately 10 kg (22 lbs.) | |
| Ordering information | HI904-01 and HI904-02 are supplied without diaphragm; HI904D-01 and HI904D-02 are supplied with diaphragm.
All Models Include: dual platinum pin electrode, air pump assembly, titration vessel assembly (glass vessel, accessory port stopper, sample port cap and septum, stir bar, desiccant, desiccant cartridge, fittings), |
|