[:lt]HI70636L Valymo tirpalas vyno dėmėms (500 ml)[:en]HI70636L Cleaning Solution for Wine Stains (500 mL)[:] — HI70636L Cleaning Solution for Wine Stains (500 mL) [:lt]HI70642L Sūrio nuosėdų valymo tirpalas (500 ml)[:en]HI70642L Cleaning Solution for Cheese Deposits (500 mL)[:] HI70642L Cleaning Solution for Cheese Deposits (500 mL) —

HI70640L Cleaning Solution for Milk Deposits (500 mL)

36.00  + PVM

The HI70640L is a highly effective cleaning solution that is specially formulated for use with pH electrodes that become coated with milk deposits.

SKU: HI70640L Category:

Available on backorder - This item may take 2-3 weeks to deliver.

The HI70640L is a highly effective cleaning solution that is specially formulated for use with pH electrodes that become coated with milk deposits. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement and stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and prevent any clogging of the junction.

Hanna’s line of cleaning solutions have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.

Specially formulated cleaning solution to remove milk deposits from a pH electrode

Air tight bottle with tamper-proof seal to ensure quality

Expiration date and lot number clearly marked on the bottle

 

Details

The most common cause for pH measurement inaccuracies is an unclean or improperly cleaned electrode. This is very important to note, because during calibration, the instrument assumes that the electrode is clean and that the standardization curve created during the calibration process will remain a valid reference until the next calibration. pH meters on the market today will allow an offset voltage of approximately ±60 mV. The deviation from 0 mV is not unusual but ideally should be no greater than ±30 mV. The calibration process compensates for the change in offset voltage. If the mV offset continues to deviate and the meter is calibrated with a dirty electrode then inaccurate readings will result.

The Cleaning Solution Series ensures maximum efficiency and accuracy of your sensors when used for it’s designated application. Cleaning is a fast and effective routine that should be performed on a regular basis as a preventative measure against using a dirty electrode and to ensure that the junction is not clogged. The HI70640L is a cleaning solution made for the dairy industry, specifically targeted for milk pH measurement applications where an electrode can become coated with milk deposits.

 

Air tight bottle with tamper-proof seal

  • Ensures quality and freshness of solution

 

Each bottle marked with lot number and expiration date

  • Hanna cleaning solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle.

Description cleaning solution for milk deposits (food industry)