[:lt]HI700636P Valymo tirpalas vyno dėmėms (25 x 20 ml paketai)[:en]HI700636P Cleaning Solution for Wine Stains (25 x 20 mL Sachets)[:] — HI700636P Cleaning Solution for Wine Stains (25 x 20 mL Sachets) [:lt]HI700641P Pieno produktų valymo ir dezinfekavimo tirpalas (25 x 20 ml paketai)[:en]HI700641P Cleaning & Disinfection Solution for Dairy Products (25 x 20 mL Sachets)[:] HI700641P Cleaning & Disinfection Solution for Dairy Products (25 x 20 mL Sachets) —

HI700640P Cleaning Solution for Milk Deposits (25 x 20 mL Sachets)

42.00  + PVM

The HI700640P is a highly effective cleaning solution that is specially formulated for use with pH electrodes that become coated with milk deposits.

SKU: HI700640P Category:

Available on backorder - This item may take 2-3 weeks to deliver.

The HI700640P is a highly effective cleaning solution that is specially formulated for use with pH electrodes that become coated with milk deposits. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement and stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and prevent any clogging of the junction.

Each sachet has the lot number and expiration date stamped on it and is made of light block foil ensuring freshness each time one is opened. Hanna’s line of cleaning solutions have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened sachet.

Specially formulated cleaning solution to remove milk deposits from a pH electrode

Convenient, one-time use sachets ensure freshness of solution

Details

The most common cause for pH measurement inaccuracies is an unclean or improperly cleaned electrode. This is very important to note, because during calibration, the instrument assumes that the electrode is clean and that the standardization curve created during the calibration process will remain a valid reference until the next calibration. pH meters on the market today will allow an offset voltage of approximately ±60 mV. The deviation from 0 mV is not unusual but ideally should be no greater than ±30 mV. The calibration process compensates for the change in offset voltage. If the mV offset continues to deviate and the meter is calibrated with a dirty electrode then inaccurate readings will result.

acid cleaning solution

The Cleaning Solution Series ensures maximum efficiency and accuracy of your sensors when used for it’s designated application. Cleaning is a fast and effective routine that should be performed on a regular basis as a preventative measure against using a dirty electrode and to ensure that the junction is not clogged. The HI700640P is a cleaning solution made for the dairy industry, specifically targeted for milk pH measurement applications where an electrode can become coated with milk deposits.

 

Light block foil packaging

  • Light-tight packet helps to prevent against degradation by UV light

 

One-time use sachet packets

  • Ensures quality and freshness of solution

 

Each sachet marked with lot number and expiration date

  • Hanna cleaning solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened sachet.
Description cleaning solution for milk deposits (food industry)
Certificate of Analysis no
Package sachets
Quantity 25
Size 20 mL

Additional information

Weight 0.673 kg

Related products