[:lt]HI83325 Maistinių medžiagų analizės fotometras NPK[:en]Nutrient Analysis Photometer - HI83325[:] — Nutrient Analysis Photometer - HI83325 [:lt]HI83308 Vandens kokybės parametrų nustatymo fotometras[:en]Water Conditioning Photometer - HI83308[:] Water Conditioning Photometer - HI83308 —

Pool and Spa Photometer – HI83326

792.00  + PVM

SKU: HI83326 Categories: ,

Available on backorder - This item may take 2-3 weeks to deliver.

HI83326 is a compact, multiparameter photometer for use in pool and spa applications. The meter is one of the most advanced photometers available with an innovative optical design that utilizes a reference detector and focusing lens to eliminate errors from changes in the light source and from imperfections in the glass cuvette. This meter has 12 different programmed methods measuring 11 key water quality parameters and also offers an absorbance measurement mode for performance verification and for users that would like to develop their own concentration versus absorbance curves. Pool and spa parameters include alkalinity, free chlorine, nitrite, and phosphate which are critical to maintaining a healthy system.

To save valuable laboratory benchtop space, the HI83326 doubles as a professional pH meter with its digital pH/temperature electrode input. Now one meter can be used for both photometric and pH measurements.

Advanced optical system

Unparalleled performance from a benchtop photometer

Digital pH electrode input

Save valuable bench space with one meter that works both as a photometer and as a laboratory pH meter

Absorbance measuring mode

Details

The HI83326 benchtop photometer measures 11 different key water quality parameters using 12 different methods. This photometer features an innovative optical system that uses LEDs, narrow band interference filters, focusing lens and both a silicon photodetector for absorbance measurement and a reference detector to maintain a consistent light source ensures accurate and repeatable photometric readings every time.

Made with the pool and spa industry in mind, a basic necessity of pool water treatment is to maintain the water in a safe and pleasant condition for the swimmers. In pool and spa water treatment, disinfection is essential to rid the pool of bacteria and control nuisance organisms like algae which may occur in the pool, spa, filtration equipment, or piping. There are a number of available disinfectant compounds including chlorine, bromine, and ozone. In order to achieve ideal water conditions, water requires testing on a daily and sometimes hourly basis to ensure there is enough residual disinfectant and to maintain pH levels. Equally important is calcium hardness and alkalinity; these levels should be monitored weekly to ensure the pool or spa water is well balanced to avoid corrosion and scale formation.

A digital pH electrode input allows the user to measure pH by a traditional glass electrode. The digital pH electrode has a built in microchip within the probe that stores all of the calibration information. Having the calibration information stored in the probe allows for hot swapping of pH electrodes without having to recalibrate. All pH measurements are automatically compensated for temperature variations with a built in thermistor located in the tip of the sensing bulb for fast and accurate temperature measurement.

The HI83326 offers an absorbance measuring mode that allows for CAL Check standards to be used to validate the performance of the system. The absorbance mode allows the user to select one of the three wavelengths of light (525 nm, 575 nm, and 610 nm) to measure and plot their own concentration versus absorbance mode. This is useful for users with their own chemical method and for educators to teach the concept of absorbance by using the Beer-Lambert Law.

Two USB ports are provided for transferring data to a flash drive or computer and to use as a power source for the meter. For added convenience and portability the meter can also operate on an internal 3.7 VDC Lithium-polymer rechargeable battery.

 

Features/Benefits:

Backlit 128 x 64 Pixel Graphic LCD Display

  • Backlit graphic display allows for easy viewing in low light conditions
  • The 128 x 64 Pixel LCD allows for a simplified user interface with virtual keys  and on-screen help to guide the user through use of the meter

Built-in Reaction Timer for Photometric Measurements

  • The measurement is taken after the countdown timer expires.
  • Countdown timer ensures that all readings are taken at the appropriate reaction intervals regardless of user for better consistency in measurements

Absorbance mode

  • Hanna’s exclusive CAL Check cuvettes for validation of light source and detector
  • Allows for the user to plot concentration versus absorbance for a specific wavelength for use with user supplied chemistry or for teaching principles of photometry

Units of Measure

  • Appropriate unit of measure along with chemical form is displayed along with reading

Result Conversion

  • Automatically convert readings to other chemical forms with the touch of a button

Cuvette Cover

  • Aids in preventing stray light from affecting measurements

Digital pH Electrode Input

  • Measure pH and temperature with a single probe
  • Good Laboratory Practice (GLP) to track calibration information including date, time, buffers used, offset and slope for traceability
  • pH CAL Check alerts user to potential problems during the calibration process
  • Space saving having a pH meter and photometer built into one meter

Data Logging

  • Up to 1000 photometric and pH readings can be stored by simply pressing the dedicated LOG button. Logged readings are just as easily recalled by pressing the RCL button
  • Sample ID and User ID information can be added to a logged reading using alphanumeric keypad

Connectivity

  • Logged readings can be quickly and easily transferred to a flash drive using the USB-A host port or to a computer using the micro USB-B port
  • Data is exported as a .CSV file for use with common spreadsheet programs

Battery Status Indicator

  • Indicates the amount of battery life left

Error Messages

  • Photometric error messages include no cap, high zero, and standard too low
  • pH calibration messages include clean electrode, check buffer and check probe
  • On-screen Features

    method selectionMethod Selection
    Users can easily select any one of the 20 measurement methods via the dedicated METHOD button.

    data loggingData Logging
    Up to 1000 measurement readings can be logged with user and sample ID and recalled for future use.

    ph measurement modepH Measurement Mode
    Selecting the pH measurement mode allows for the photometer to be used as a professional pH meter with many features including temperature compensated measurements, automatic two point calibration, and GLP.

    Advanced Optical System

    HI83326 is designed with an innovative optical system that incorporates a beam splitter so that light can be used for absorbance readings and for a reference detector. The reference detector monitors the intensity of light and modulates when there is drift due to power fluctuation or the heating of the optical components. Each part has an important role in providing unparalleled performance from a photometer.

     

    photometer multiparameter optical

    High Efficiency LED Light Source

    An LED light source offers superior performance as compared to a tungsten lamp. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce very little heat, which could otherwise affect the optical components an electronic stability. LEDs are available in a wide array of wavelengths, whereas tungsten lamps are supposed to be white light (all wavelengths of visible light) but actually have a poor blue/violet light output.

    High Quality Narrow Band Interference Filters

    The narrow band interference filter not only ensure greater wavelength accuracy (+/- 1 nm) but are extremely efficient. The filters used allow up to 95% of the light from the LED to be transmitted as compared to other filters that are only 75% efficient. The higher efficiency allows for a brighter, stronger light source. The end result is higher measurement stability and less wavelength error.

    Reference Detector for a Stable Light Source

    A beam splitter is used as part of the internal reference system of the HI83326 photometer. The reference detector compensates for any drift due to power fluctuations or ambient temperature changes. Now you can rely on a stable source of light between your blank (zero) measurement and sample measurement.

    Large Cuvette Size

    The sample cell of the HI83326 fits a round, glass cuvette with a 25 mm path length. Along with the advanced optical components, the larger size of the cuvette greatly reduces errors in rotation from the indexing mark of the cuvettes. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.

    Focusing Lens for Greater Light Yield

    Adding a focusing lens to the optical path allows for the collection of all of the light that exits the cuvette and focusing the light on the silicon photo detector. This novel approach to photometric measurements cancels the errors from imperfections and scratches present in the glass cuvette eliminating the need to index the cuvette.

     

    pH Range Photometer: 6.5 to 8.5 pH 
    pH electrode: -2.00 to 16.00 pH
    pH Resolution Photometer: 0.1 pH 
    pH electrode: 0.01 pH
    pH Accuracy Photometer: ±0.1 pH 
    pH electrode: ±0.01 pH
    pH Calibration Automatic one or two point calibration with one set of standard buffers available (4.01, 6.86, 7.01, 9.18, 10.01)
    pH Temperature Compensation Automatic (-5.0 to 100.0 oC; 23.0 to 212.0 oF); limits reduced based on the pH electrode used
    pH CAL Check (electrode diagnostics) clean electrode and check buffer/check probe displayed during calibration
    pH Method Photometer: phenol red
    pH-mV Range ±1000 mV
    pH-mV Resolution 0.1 mV
    pH-mV Accuracy ±0.2 mV
    Absorbance Range 0.000 to 4.000 Abs
    Absorbance Resolution 0.001 Abs
    Absorbance Accuracy +/-0.003Abs @ 1.000 Abs
    Alkalinity Range Freshwater: 0 to 500 mg/L (as CaCO3)
    Alkalinity Resolution 1 mg/L
    Alkalinity Accuracy ±5 mg/L ±5% of reading
    Alkalinity Method Colorimetric method
    Bromine Range 0.00 to 8.00 mg/L (as Br2)
    Bromine Resolution 0.01 mg/L
    Bromine Accuracy ±0.08 mg/L ±3% of reading
    Bromine Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method.
    Free Chlorine Range 0.00 to 5.00 mg/L (as Cl2)
    Free Chlorine Resolution 0.01 mg/L
    Free Chlorine Accuracy ±0.03 mg/L ±3% of reading
    Total Chlorine Range 0.00 to 5.00 mg/L (as Cl2)
    Total Chlorine Resolution 0.01 mg/L
    Total Chlorine Accuracy ±0.03 mg/L ±3% of reading
    Chlorine Method Adaptation of the EPA 330.5 DPD method
    Copper Range High range: 0.00 to 5.00 mg/L (as Cu2+)
    Copper Resolution 0.01 mg/L
    Copper Accuracy High Range ±0.02 mg/L ±4% of reading
    Copper Method Adaptation of the EPA bicinchoninate method
    Cyanuric Acid Range 0 to 80 mg/L (as CYA)
    Cyanuric Acid Resolution 1 mg/L
    Cyanuric Acid Accuracy ±1 mg/L ±15% of reading
    Cyanuric Acid Method Adaptation of the turbidimetric method
    Hardness, Calcium Range 0.00 to 2.70 mg/L (as CaCO3)
    Hardness, Calcium Resolution 0.01 mg/L
    Hardness, Calcium Accuracy ±0.11 mg/L ±5% of reading
    Hardness, Calcium Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Calmagite method
    Iron Range High Range: 0.00 to 5.00 mg/L (as Fe)
    Iron Resolution 0.01 mg/L
    Iron Accuracy High Range: ±0.04 mg/L ±2% of reading
    Iron Method Adaptation of Standard Methods for the Examination of Water and Wastewater, 3500-Fe B., Phenanthroline Method
    Nitrate Range 0.0 to 30.0 mg/L (as NO3– N)
    Nitrate Resolution 0.1 mg/L
    Nitrate Accuracy ±0.5 mg/L ±10% of reading
    Nitrate Method Adaptation of the cadmium reduction method
    Ozone Range 0.00 to 2.00 mg/L (as O3)
    Ozone Resolution 0.01 mg/L
    Ozone Accuracy ±0.02 mg/L ±3% of reading
    Ozone Method Colorimetric DPD Method
    Phosphate Range Freshwater
    Low Range: 0.00 to 2.50 mg/L (as PO43-)
    Phosphate Resolution Freshwater: 0.01 mg/L
    Phosphate Accuracy Freshwater
    Low Range: ±0.04 mg/L ±4% of reading
    Phosphate Method Freshwater Low Range: Adaptation of the Ascorbic Acid method
    Input Channels 1 pH electrode input and 3 photometer wavelengths
    pH Electrode digital pH electrode (not included)
    Photometer/Colorimeter Light Source 3 LEDs with 525 nm, 575 nm, and 610 nm narrow band interference filters
    Photometer/Colorimeter Light Detector silicon photodetector
    Bandpass Filter Bandwidth 8 nm
    Bandpass Filter Wavelength Accuracy ±1 nm
    Cuvette Type round, 24.6 mm
    Number of Methods 128 max.
    GLP calibration data for connected pH electrode
    Display 128 x 64 pixel LCD with backlight
    Logging Type log on demand with user name and sample ID optional input
    Logging Memory 1000 readings
    Connectivity USB-A host for flash drive; micro-USB-B for power and computer connectivity
    Power Supply 5 VDC USB 2.0 power adapter with USB-A to micro-USB-B cable (included)
    Battery Type/Life 3.7 VDC Li-polymer rechargeable battery / >500 photometric measurements or 50 hours of continuous pH measurement
    Environment 0 to 50.0 oC (32 to 122.0 oF); 0 to 95% RH, non-condensing
    Weight 1.0 kg (2.2 lbs.)
    Dimensions 206 x 177 x 97 mm (8.1 x 7.0 x 3.8″)
    Ordering Information HI83226 is supplied with sample cuvettes and caps (4 ea.), cloth for wiping cuvettes, USB to micro USB cable connector, power adapter and instruction manual.

Related products