The HI97115 is a compact and versatile Marine multiparameter photometer designed to accurately determine pH, Alkalinity, Ammonia, Calcium, Magnesium, Nitrate, Nitrite, and Phosphate levels in aquariums and marine biology applications. The HI97115 is suitable for field and bench measurements.
The HI97115 can be used as a stand-alone photometer or can be connected to the Hanna Lab App with a compatible smart device via the integrated Bluetooth module. When connected, Hanna Lab App functions include measurement with the ability to add notes, data logging with extended storage capacity, data sharing, and the ability to create and save method groups.
Precise and advanced LED optical system
Innovative optical design that utilizes a reference detector and focusing lens to eliminate errors from changes in the light source and from imperfections in the glass cuvette. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce little heat, which could otherwise affect electronic stability.
Features of HI97115 Portable Photometer:
- Waterproof and floating IP67 meter design
- Backlit LCD and on-screen help to guide users
- Option to select measurement location for better tracking consistency
- Built-in reaction timer that ensures consistency between tests
- CAL Check™ validation and calibration.
Validate instrument performance at any time using CAL Check cuvettes made with NIST traceable standards. The CAL Check screen guides the user step-by-step through the validation process and user calibration. GLP data displays the last calibration date. - On-screen tutorial mode with animations
The built-in tutorial mode guides users step-by-step through the measurement process. It includes all steps required for sample preparation, the required reagents and quantities. Tutorial mode can be easily enabled or disabled from the setup menu. - Includes auto-data logging features to easily record water testing results
The instrument features a data autolog function to help users keep track of all measurements. Every time a measurement is made the data is automatically saved. The data log can hold 200 individual measurements. When the data log is full (200 data points), the meter will rewrite the oldest data point. - Positive locking system
The Hanna positive-locking system ensures cuvettes are placed into the holder in the same position every time.
Specifications
Specifications | HI97115 pH, Alkalinity, Ammonia, Calcium, Magnesium, Nitrate, Nitrite, and Phosphate levels | |
Marine pH
|
Range | 6.3 to 8.6 pH |
Resolution | 0.1 pH | |
Accuracy | ±0.2 pH of reading at 25 °C | |
Method | Colorimetric Adaptation of the Phenol Red Method | |
LED | 525 nm | |
Marine Alkalinity
|
Range | 0.0 to 20.0 dKH |
Resolution | 0.1 dKH | |
Accuracy | ±0.3 dKH ±5 % of reading at 25 °C | |
Method | Colorimetric MethodThe reaction causes a distinctive range of colors from yellow to greenish blue to develop. | |
LED | 610 nm | |
Marine Ammonia
|
Range | 0.00 to 2.50 ppm (as NH₃) |
Resolution | 0.01 ppm | |
Accuracy | ±0.05 ppm ±5% of reading at 25 °C | |
Method | Adaptation of the Salicylate MethodThe reaction between Ammonia and Ammonium and the reagent causes a blue-green tint in the sample | |
LED | 610 nm | |
Marine Calcium
|
Range | 200 to 600 ppm |
Resolution | 1 ppm | |
Accuracy | ±6% of reading at 25 °C | |
Method | Adaptation of the Zincon Method | |
LED | 610 nm | |
Marine Magnesium
|
Range | 1000 to 1800 ppm (as Mg2+) |
Resolution | 5 ppm | |
Accuracy | ±5% of reading at 25 °C | |
Method | Adaptation of the Colorimetric EDTA Method using calmagite indicator The reaction between magnesium and the reagents causes a blue to violet tint in the sample. | |
LED | 610 nm | |
Marine Nitrate LR
|
Range | 0.00 to 5.00 ppm (as NO₃–) |
Resolution | 0.01 ppm | |
Accuracy | ±0.25 ppm ±2% of reading at 25 °C | |
Method | Zinc Reduction Method The reaction between nitrate and the reagent causes a pink tint in the sample |
|
LED | 525 nm | |
Marine Nitrate HR
|
Range | 0.0 to 75.0 ppm (as NO₃–) |
Resolution | 0.1 ppm | |
Accuracy | ±2.0 ppm ±5% of reading at 25 °C | |
Method | Zinc Reduction Method The reaction between nitrate and the reagent causes a pink tint in the sample |
|
LED | 525 nm | |
Marine Nitrite ULR
|
Range | 0 to 200 ppb (as NO₂–-N) |
Resolution | 1 ppb | |
Accuracy | ±10 ppb ±4% of reading at 25 °C | |
Method | Adaptation of the EPA Diazotization Method 354.1 The reaction between nitrite and the reagent causes a pink tint in the sample |
|
LED | 525 nm | |
Marine Phosphate ULR
|
Range | 0.00 to 0.90 ppm |
Resolution | 0.01 ppm | |
Accuracy | ±0.02 ppm ±5% of reading at 25 °C | |
Method | Adaptation of Standard Methods for the Examination of Water and Wastewater, 20th Edition, Ascorbic Acid Method |
|
LED | 610 nm | |
Measurement System
|
Light source | LED |
Bandpass filter | wavelength 525 nm & 610 nm bandwidth 8 nm wavelength accuracy ±1.0 nm |
|
Light detector | silicon photocell | |
Cuvette Type | round 24.6 mm diameter (22 mm inside diameter) |
Additional Specifications
|
Auto logging | 200 readings |
Display | 128 x 64 pixel B/W LCD with backlight | |
Casing | IP67 rating, floating | |
Auto-of | after 15 minutes of inactivity (30 minutes before a READ measurement) |
|
Dimensions | 142.5 x 102.5 x 50.5 mm (5.6 x 4.0 x 2.0″) | |
Environment | 0 to 50 °C (32 to 122 °F); 0 to 100% RH, nonserviceable | |
Weight | 380 g (13.4 oz.); with batteries | |
Battery type / Life | Alkaline 1,5V AA (3) / approximately 800 measurements without backlight |
Ordering Information:
HI97115 is supplied with sample cuvette (2 pcs.); sample cuvette cap (2 pcs.); 1.5V AA alkaline batteries (3 pcs.); instrument quality certificate; and quick reference guide with instructions for manual download.
* CAL Check standards and testing reagents sold separately
* CAL Check standards and testing reagents sold separately
HI97115C** is delivered in a rugged carrying case and is supplied with sample cuvette (2 pcs.); sample cuvette cap (2 pcs.); marine pH reagent, 30 mL dropper (1 pc.), Marine Alkalinity reagent, 30 mL bottle (1 pc.); Marine Ammonia starter kit – reagent A, 30 mL dropper (1 pc.), reagent B and C (reagent for 25 tests, each); Marine Calcium starter kit – reagent A, 30 mL bottle (1 pc.), reagent B (reagent for 25 tests); Marine Magnesium starter kit – reagent A, 120 mL bottle (1 pc.); Magnesium indicator reagent (for 25 tests); Marine Nitrate High Range reagent (reagent for 25 tests); Marine Nitrite Ultra Low Range reagent (reagent for 25 tests); Marine Phosphate Ultra Low Range reagent (reagent for 25 tests); 1 mL graduated syringe with tip (3 pcs.); minipipette with tip (1 pc.); 3 mL Pasteur pipette (2 pcs.); 5 mL syringe with black printing and tip (1 pc.); 5 mL syringe with blue printing and tip (1 pc.); 1.5V AA alkaline batteries (3 pcs.); cloth for wiping cuvettes; scissors; instrument quality certificate; and quick reference guide with instructions for manual download.
* CAL Check standards sold separately. Nitrate LR testing reagent not included.
* CAL Check standards sold separately. Nitrate LR testing reagent not included.
Accessories:
HI97105-11 CAL Check™ standards for Marine Master photometer – cuvette kit
HI758-26 marine calcium reagent – 25 tests
HI764-25 marine nitrite ULR reagent – 25 tests
HI772-26 marine alkalinity reagent – 25 tests
HI774-25 marine phosphate ULR reagent – 25 tests
HI780-25 marine pH Reagent – approx. 100 tests
HI781-25 marine nitrate LR reagent – 25 tests
HI782-25 marine nitrate HR reagent – 25 tests
HI783-25 marine magnesium reagent – 25 tests
HI784-25 marine ammonia reagent – 25 tests
HI70436M Deionized water (230 mL)
HI7101419 Blue carrying case for HI97115C
HI731318 Cloth for wiping cuvettes (4 pcs.)
HI731331 Glass cuvette (4 pcs.)
HI731360 Glass cuvette with cap (2 pcs.)
HI731336N Cap for glass cuvette (4 pcs.)
HI731339P 0.1 mL minipipette
HI731349P Tip for 0.1 mL minipipette (10 pcs.)
HI740142P 1 mL graduated syringe (10 pcs.)
HI740143 1 mL graduated syringe (6 pcs.)
HI740144P Plastic tip for 5 mL syringe (10 pcs.)
HI740157P Plastic refilling pipette (20 pcs.)
HI740226 5 mL graduated syringe with black printing (1 pc.)
HI740237 5 mL graduated syringe with blue printing (1 pc.)
HI97105-11 CAL Check™ standards for Marine Master photometer – cuvette kit
HI758-26 marine calcium reagent – 25 tests
HI764-25 marine nitrite ULR reagent – 25 tests
HI772-26 marine alkalinity reagent – 25 tests
HI774-25 marine phosphate ULR reagent – 25 tests
HI780-25 marine pH Reagent – approx. 100 tests
HI781-25 marine nitrate LR reagent – 25 tests
HI782-25 marine nitrate HR reagent – 25 tests
HI783-25 marine magnesium reagent – 25 tests
HI784-25 marine ammonia reagent – 25 tests
HI70436M Deionized water (230 mL)
HI7101419 Blue carrying case for HI97115C
HI731318 Cloth for wiping cuvettes (4 pcs.)
HI731331 Glass cuvette (4 pcs.)
HI731360 Glass cuvette with cap (2 pcs.)
HI731336N Cap for glass cuvette (4 pcs.)
HI731339P 0.1 mL minipipette
HI731349P Tip for 0.1 mL minipipette (10 pcs.)
HI740142P 1 mL graduated syringe (10 pcs.)
HI740143 1 mL graduated syringe (6 pcs.)
HI740144P Plastic tip for 5 mL syringe (10 pcs.)
HI740157P Plastic refilling pipette (20 pcs.)
HI740226 5 mL graduated syringe with black printing (1 pc.)
HI740237 5 mL graduated syringe with blue printing (1 pc.)
HI740228 Filter disc (25 pcs.)
HI740270 10 mL syringe with Luer Lock (1 pc.)
HI740271 Filter holder with Luer Lock (1 pc.)
HI740272 16 gauge blunt needle (6 pcs.)
HI740273 Marine Nitrate LR measurement kit (1 pc.)
HI93703-50 Cuvette cleaning solution (230 mL)
HI740270 10 mL syringe with Luer Lock (1 pc.)
HI740271 Filter holder with Luer Lock (1 pc.)
HI740272 16 gauge blunt needle (6 pcs.)
HI740273 Marine Nitrate LR measurement kit (1 pc.)
HI93703-50 Cuvette cleaning solution (230 mL)