[:lt]K-tipo aštrus termoporos zondas - HI766PC[:en]Penetration K-Type Thermocouple Probe - HI766PC[:] — Penetration K-Type Thermocouple Probe - HI766PC [:lt]HI98703 Didelio tikslumo nešiojamas drumstumo matuoklis[:en]HI98703 High accuracy (±2% of reading plus 0.02 NTU) Turbidity Portable Meter.[:] HI98703 High accuracy (±2% of reading plus 0.02 NTU) Turbidity Portable Meter. —

HI93414 High accuracy Turbidity and Chlorine Portable Meter

1,419.00  + PVM

Drumstumo ir chloro matuoklis (laisvas/bendras cl) su Fast Tracker™ Technologija; matavimo interrvalas nuo 0.00 iki 1000 NTU, laisvas Cl2 0.00 iki 5.00 mg/L; bendras Cl2 0.00 iki 5.00 mg/L.

SKU: HI93414 Category:

Available on backorder - This item may take 2-3 weeks to deliver.

The HI93414 is a high accuracy Turbidity and Chlorine Portable Meter. This meter is a combination of a nephelometer and photometer to measure the most important parameters in drinking water: turbidity and chlorine. The meter is supplied complete with AMCO-AEPA-1 primary turbidity standards and NIST traceable secondary chlorine standards used for calibration and performance verification. The HI93414 meets and exceeds the requirements of EPA Method 180.1 and Standard Methods for the Examination of Water and Wastewater 2130 B for turbidity measurements.The chlorine measurements are are adapted EPA Method 330.5 and Standard Method 4500-Cl G.

Fast Tracker – Tag Identification System (T.I.S)

USB for data transfer

Operates on batteries or line voltage

 

Details

The HI93414 is a multiparameter instrument that measures the most important parameters in drinking water: turbidity and chlorine. The instrument is based on a state-of-the-art optical system which provides accurate results by minimizing stray light and color interferences. Periodic calibration with the supplied standards compensates for any variations in intensity of the tungsten lamp. The colorimeter portion of the meter uses a 525 nm narrow band interference filter for maintaining the proper wavelength in the measurement of free and total chlorine. All measurements are performed with 25 mm round cuvettes composed of special optical glass to ensure maximum repeatability of turbidity and chlorine measurements.

 

Features at-a-glance:

Three Measurement Modes – The HI93414 features three options for measurement including ratio mode for turbidity, free chlorine, and total chlorine. Turbidity measurements can be made in the 0.00 to 1000 NTU (Nephelometric Turbidity Units) range, while free or total chlorine measurements can be made in the 0.00 to 5.00 mg/L (ppm) range.

Multiple reading modes – Normal measurement, continuous measurement, or signal averaging measurement are reading modes available

EPA Compliant –  The HI93414 meets and exceeds the requirements of EPA and Standard Methods both for turbidity and colorimetric chlorine measurements. When the meter is in EPA mode all turbidity readings are rounded accordingly to meet reporting requirements.

Calibration – A two, three, or four-point turbidity calibration can be performed by using the supplied (<0.10, 15.0, 100, and 750 NTU) standards. Calibration points can be modified if user-prepared standards are used. For free and total chlorine, the 1.00 mg/L (ppm) CAL Check standard can be used for calibration and performance verification.

AMCO AEPA-1 Primary Turbidity Standard – The AMCO AEPA-1 supplied standards are recognized as a primary standard by the USEPA. These non-toxic standards are made of styrene divinylbenzene polymer spheres that are uniform in size and density. The standards are reusable and stable with a long shelf life.

CAL Check  – With the powerful CAL Check function, reliable performance of the chlorine colorimeter can be validated at any moment by using the exclusive HANNA ready-made, NIST traceable standards.  All standards are supplied with a Certificate of Analysis (COA) for traceability.

Fast Tracker  – For advanced ˜field applications, the HI93414 is equipped with Fast Tracker – Tag Identi˜fication System (T.I.S.) that makes data collecting and management simpler than ever. Fast Tracker allows users to record the time and location of a speci˜fic measurement or series of measurements using iButton® tags near sampling points for quick and easy readings. Each iButton® tag contains a computer chip with a unique identi˜cation code encased in stainless steel.

GLP Data – The HI93414 features complete GLP (Good Laboratory Practice) functions that allow traceability of the calibration conditions. Data includes calibration points, date, and time.

Data Logging – Up to 200 measurements can be stored in the internal memory and recalled at any time.

Data Transfer – For further storage or analysis options, logged data can be downloaded to a Windows compatible PC using the RS232 or USB ports and the HI92000 software.

Backlit Display – A backlit LCD display provides an easy to understand, user-friendly interface. Displayed codes guide the user step-by-step through routine operation and calibration.

The HI98703-11 AMCO AEPA-1 standards ensure that measurements are traceable to a primary reference materials. These standards are used for calibration and performance verification of the HI93414 turbidity meter.

Turbidity Standards

Pateikiamas su analizės sertifikatu, kuriame nurodomas

  • Lot meris
  • Galiojimo data
  • Standartinė vertė @ 25 °C
  • NIST atsekamumas

HI98703-11 AMCO AEPA-1 standartai užtikrina, kad matavimai būtų atsekami iki pirminių etaloninių medžiagų. Šie standartai naudojami drumstumo matuoklio kalibravimui ir veikimo patikrinimui.

cal check standards

CAL Check™ standatai su sertifikatais

HI93414-11 laisvo ir bendro chloro CAL Check ™ standartai naudojami HI93414 kalibravimui ir veikimo patikrinimui.

Pateikiamas su analizės sertifikatu, kuriame nurodomas

  • Lot meris
  • Galiojimo data
  • Standartinė vertė @ 25 °C
  • NIST atsekamumas
  • CAL Check™ standards with certificate

    The HI93414-11 free and total chlorine CAL Checkstandards are used for calibration and performance verification of the HI93414.

    Supplied with Certificate of Analysis

    • Lot number
    • Expiration date
    • Standard value @ 25 °C
    • Reference meter NIST traceable

    Provided storage containers

    • Light tight
    • Protects from accidental breakage

     

    Turbidity Range 0.00 to 9.99; 10.0 to 99.9; 100 to 1000 NTU
    Turbidity Resolution 0.01; 0.1; 1 NTU
    Turbidity Accuracy ±2% of reading plus 0.02 NTU
    Turbidity Repeatability ±1% of reading or 0.02 NTU, whichever is greater
    Turbidity Stray Light < 0.02 NTU
    Turbidity Calibration two, three, or four-point calibration
    Turbidity Measuring Method ratio nephelometric method (90° & 180°)
    Turbidity Measuring Modes normal, average, continuous
    Turbidity Light Source tungsten filament lamp
    Turbidity Light Detector silicon photocell
    Free Chlorine Range 0.00 to 5.00 mg/L
    Free Chlorine Resolution 0.01 mg/L from 0.00 to 3.50 mg/L; 0.10 above 3.50 mg/L
    Free Chlorine Accuracy ±0.02 mg/L @ 1.00 mg/L
    Total Chlorine Range 0.00 to 5.00 mg/L
    Total Chlorine Resolution 0.01 mg/L from 0.00 to 3.50 mg/L; 0.10 above 3.50 mg/L
    Total Chlorine Accuracy ±0.02 mg/L @ 1.00 mg/L
    Chlorine Method Adaptation of the USEPA Method 330.5 and Standard Method 4500-Cl G. The reaction between chlorine and DPD reagent causes a pink tint in the sample.
    Logging Memory 200 records
    Connectivity USB or RS232
    Automatic Shut-Off auto-off after 15 minutes of non-use
    Display 40 x 70 mm graphic LCD (64 x 128 pixels) with backlight
    Battery Type/Life 4 (1.5V) AA alkaline batteries
    Power Supply 4 (1.5V) AA alkaline batteries or AC adapter
    Environment 0 to 50°C (32 to 122°F), RH max 95% non-condensing
    Dimensions 224 x 87 x 77 mm (8.8 x 3.4 x 3.0”)
    Weight 512 g (18 oz.)
    Photometer/Colorimeter Light Source Tungsten filament lamp
    Photometer/Colorimeter Light Detector Silicon photocell with 525 nm narrow band interference filters
    Ordering Information HI93414 is supplied with sample cuvettes and caps (5), calibration cuvettes for turbidity and chlorine, silicone oil, cuvette wiping cloth, scissors, batteries, AC adapter, instruction manual, and rugged carrying case.