[:lt]Pažangus ištirpusio deguonies matuoklis su polarografiniu DO zondu - HI6421P[:en]Advanced Dissolved Oxygen Meter with Polarographic DO Probe - HI6421P[:] — Advanced Dissolved Oxygen Meter with Polarographic DO Probe - HI6421P [:lt]GroLine maistinių medžiagų testeris - HI98330[:en]GroLine Nutrient Tester - HI98330[:] GroLine Nutrient Tester - HI98330 —

Advanced Dissolved Oxygen Meter with Optical DO Probe – HI6421

1,595.00  + PVM

HI6421 is a streamlined dissolved oxygen benchtop meter supplied with Hanna’s optical dissolved oxygen probe (opdo®) and features a large touch screen display for fresh and saltwater measurements.

SKU: HI6421 Categories: ,

Available on backorder - This item may take 2-3 weeks to deliver.

HI6421 is a streamlined benchtop meter with a large touch screen display, comprised of a housing and an integrated module designed for fresh and saltwater measurements of dissolved oxygen. HI6421 includes Hanna’s HI7641133 optical dissolved oxygen probe (opdo®) that is based on the principle of fluorescence quenching. An immobilized Pt-based luminophore is excited by the light of a blue LED and emits a red light. As oxygen interacts with the luminophore it reduces the intensity and lifetime of the luminescence. The lifetime of the luminescence is measured by a photodetector and is used to calculate the dissolved oxygen concentration.

The probe is fitted with easy to use Smart Caps (HI764113-1) which lock in place and contain pre-loaded calibration coefficients that are automatically transmitted to the probe. The Smart Cap features an immobilized O₂ sensitive luminophore with rugged insoluble black oxygen permeable protective layer. Over time, the sensor’s optical components can age but are compensated for by using the reference signal to compensate the measuring path. As a result, the sensor provides accurate DO measurements over long periods of time without the need for frequent calibration.

Concentration measurements are automatically compensated for barometric pressure, temperature, and salinity. Barometric pressure and temperature are automatically measured and compensated. Salinity is automatically compensated by setting manually the salinity concentration of the water being measured.Pressure compensation is done automatically (built-in barometer) or users have the option to manually enter required value. Pressure is displayed in user-configurable units: mmHg, mbar, kPa, inHg, psi, atm.

User interface

  • 7-inch capacitive touch screen with multi-touch support
  • Capacitive touch back, home and system menu keys
  • User-friendly icons and symbols allow users to easily navigate and interpret the instrument functions.

The user can select between five different views

  • Basic measurement configuration
  • Simple GLP with calibration information
  • Full GLP with electrode status and calibration point details
  • Live updated, interactive graph
  • Tabulated data with date, time, and notes

Measurement

  • Measure %Sat, mg/L, ppm (DO)
  • Application-specific profiles allow quick and direct measurement without the need to update the sensor and system settings
  • Active log during measurement
  • Measurement stability indicator (using the Stability Criteria setting)
  • Reading modes: direct and direct/autohold
  • Temperature compensation can be Automatic or set manually
  • Audible and/or alarm messages for measurements outside of predefined limits
  • Galvanic isolation for measurement

Calibration

  • One or two points calibration at 0% and/or 100% saturation
  • Single point manual calibration in mg/L or % saturation using a reference method
  • Non-volatile memory saves data and settings

Logging

  • Data log collection of at least 1,000,000 data points (with time and date stamp)
  • Logging types: manual, automatic, autohold
  • Sample ID for manual and Autohold data

Connectivity features & services

  • Transfer logged data to a USB thumb drive
  • Log files that include measurements and calibration data (as .csv file)
  • FTP and email for log export via Ethernet and Wi-Fi connection
  • USB type A for USB stick, keyboard, and printer
  • USB type C for USB stick and PC connection

Help section for meter guidance

  • Video support presentation of main functionalities

Primary Applications:

  • Fresh water and saltwater applications, aquaculture, aquariums, environmental.

 

Specifications: 

DO (HI7641133 Optical probe)
Range
0.00 to 50.00 mg/L (ppm) concentration; 0.0 to
500.0 % saturation
Resolution 0.01 mg/L (ppm); 0.1 % saturation
Accuracy
from 0.00 to 20.00 mg/L (ppm) 1.5 % of reading or
± 0.01 mg/L (ppm), whichever is greater
from 20.00 to 50.00 mg/L (ppm) ±5 % of reading
from 0.0 to 200.0 % saturation ± 1.5 % of reading
or ± 0.1 %, whichever is greater
from 200.0 to 500.0 % saturation ±5 % of reading
Barometric
Pressure
Range 450 to 850 mmHg; 600 to 1133 mBar; 60 to 133
kPa;
17 to 33 inHg; 8.7 to 16.4 psi; 0.592 to 1.118 atm
Resolution 1 mmHg; 1 mBar; 1 kPa; 1 inHg; 0.1 psi; 0.001 atm
Accuracy ±3 mmHg within ±15 % from the calibration point
±3 mmHg ±1 least significant digit
Temperature
Range −20.0 to 120.0 °C
−4.0 to 248.0 °F
253.0 to 393.0 K
Resolution 0.1 °C; 0.1 °F; 0.1 K
Accuracy ±0.2 °C; ±0.4 °F; ±0.2 K
DO Calibration
Points
One or two points automatic calibration at 100%
(8.26 mg/L) and 0% (0 mg/L).
Single point manual using a value entered by the
user in % saturation or mg/L.
Standards 0 and 100% saturation
Reminder Disabled
Daily: 0 min. to 23 hours and 59 min.
Periodic: 1 min. to 500 days, 23 hours and 59 min.
Temperature
Compensation    

 

Salinity
Compensation
Automatic or Manual

 

 
Automatic from 0 to 70 PSU (manually set)
0.0 to 70.0 % / 0.0 to 45.0 g/L / 0.0 to 42.0 psu

 

Reading
Modes Direct
Direct/Autohold
Stability criteria Accurate
Medium
Fast
Isopotential 7.000 or 4.010
Sampling rate 1000 ms
DO Views
Basic Measurement (DO, Temperature)
Stability status
Simple GLP Basic view information
Last calibration date, offset, average slope
Full GLP Simple GLP information and calibration point details
Table Measurements updated every second are displayed in table
Graph (Plot) Measurement versus time graph can be panned or zoomed (pinch-to-zoom technology)
Logging
Type Automatic, Manual, Autohold
Number of records 50 000 maximum perfile
Stores at least 1 000 000 data points per user
Automatic interval 1, 2, 5, 10, 30 seconds
1, 2, 5, 10, 15, 30, 60, 120, 150, 180 minutes
Sample ID Incremental mode
Export option .csv file format
Users Up to 9 users and the default administrator account
Connectivity
USB-A 2 ports for keyboard input or USB thumb drive
USB-C 1 port for PC connectivity and USB-C type thumb drive
Wi-Fi & Ethernet FTP
Web server
Log transfer and download
Email
RS232 Connecting peripherals
Power supply DC adapter 100-240AC to 24VDC 2.5A
Environment 0 – 50 °C / 32 – 122 °F / 273 – 323 K maximum 95% RH non-condensing
Dimensions 205 x 160 x 77 mm (8.0 x 6.2 x 3.0 “)
Weight Approximately 1.2 kg (26.5 lbs.)
Ordering Information