[:lt]Bendram chlorui matuoti labai mažose koncentracijose[:en]Total Chlorine Checker Ultra Low Range (0 to 500 ppb)[:] — Total Chlorine Checker Ultra Low Range (0 to 500 ppb) [:lt]Silicio nustatymui didelėse koncentracijose,  0 - 200 mg/l[:en]Silica HR Checker HC®, 0 to 200 ppm[:] Silica HR Checker HC®, 0 to 200 ppm —

Nitrite ultra low range Checker HC®: Range 0 to 200 ppb (ug/ml)

60.50  + PVM

The HI764 Checker® Handheld Colorimeter bridges the gap between simple chemical test kits and professional instrumentation. Range 0 -200 ppb (ug/ml).

SKU: HI764 Category: Tag:

Available on backorder - This item may take 2-3 weeks to deliver.

The Hanna Checker® bridges the gap between simple chemical test kits and professional instrumentation. Chemical test kits are not very accurate and only give 5 to 10 points resolution while professional instrumentation can cost hundreds of dollars and can be time-consuming to calibrate and maintain. The Checker® is both accurate and affordable.

checker compact and portable meter

Compact, portable design

checker built-in timer

Built-in timer

checker one-button operation

One-Button operation

 

Details

Nitrification is the biological oxidation of ammonia (ammonium ion) into nitrite followed by the oxidation of the nitrites to nitrates. The first step of this 2-step process is carried out in an aquarium by nitrifying bacteria. During this quick process, the ammonium levels drop while the nitrite levels increase. Since nitrite is just as harmful as ammonia, nitrite levels should be maintained at immeasurable levels. A mature biological filter should be able to keep nitrite levels low.

Also, if tap water is to be used in an aquarium, it is recommended that it be tested for phosphate, as well as silicate, ammonia, nitrate, nitrite, pH, and alkalinity.

The HI764 Checker® Handheld Colorimeter bridges the gap between simple chemical test kits and professional instrumentation. Chemical test kits are not very accurate, while professional instrumentation can cost hundreds of dollars and can be time-consuming to calibrate and maintain. Hanna Checker®’s are accurate, affordable and easy to use.

To begin measurements, first, zero the instrument with your water sample. Next, add the reagent. Last, place the vial into the Checker®, press the button and read the results. It’s that easy.

The contoured style of these Checker®’s fit in your palm and pocket perfectly and the large LCD is easy to read. The auto shut-off feature assures the battery life will not be drained if you forget to turn it off.

How to use Hanna Checker Handheld Colorimeter

Features at-a-glance:

  • Easier to use and more accurate than chemical test kits
  • Dedicated to a single parameter
  • Small size, big convenience
  • Ideal for: Water quality, Environmental, Plating, Education

Video

Wistia video thumbnail

 
 
Nitrite Range 0 to 200 ppb (ug/ml)
Nitrite Resolution 1 ppb (ug/ml)
Nitrite Accuracy ±10 ppb ±4% of reading
Nitrite Method adaptation of the EPA Diazotization method 354.1.
Photometer/Colorimeter Light Source LED @ 525 nm
Photometer/Colorimeter Light Detector silicon photocell
Battery Type/Life (1) 1.5V AAA
Automatic Shut-Off after two minutes of non-use
Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing
Weight 64 g (2.25 oz.)
Dimensions 81.5mm x 61mm x 37.5mm (3.2″ x 2.4″ x 1.5”)
Ordering Information HI764 Checker® is supplied with (2) sample cuvettes with caps, nitrite ULR reagent starter kit for 6 tests (6 powder reagent packets), battery, instructions and quick start guide.